CLEANING AND MAINTENANCE (CONTINUED)
D. Lubricate the swivel on the discharge boom assembly and the swivel on the hose
reel.
E. If equipped with the Air Flush Option, refer to the Air Flush System Manual.
F. Check the level in the hydraulic oil reservoir; maintain level with the sight gauge.
WEEKLY OR EVERY 40 HOURS OF OPERATION
1. Clean the air cleaner following the instructions in the engine operator’s manual.
2. Lubricate all the points on the HydroSeeder
®
as outlined in DAILY section of the
CLEANING AND MAINTENANCE section and the LUBRICATION AND FLUIDS CHART
section. Additionally, lubricate the four grease fittings on the clutch/pump.
3. Check the slurry pump clutch adjustment to ensure that it “snaps” in and out of
engagement. Adjust the clutch with the engine off.
4. Check the anti freeze in the radiator.
5. Inspect the slurry tank for build-up of residue in the suction area and clear if necessary.
6. Check and clean engine radiator fins. Flush with clear, low-pressure water and blow dry
with compressed air. Do NOT use high-pressure water spray or damage to the radiator
fins will occur.
7. Check pivoting hose reel swivel bolt and replace bolts if any show signs of wear.
SEASONAL AND WINTER STORAGE MAINTENANCE
1. Drain the slurry tank of all water, prior to storage, and leave the drain plug uninstalled.
2. If possible, cover machine with tarp or park inside of an enclosure.
3. Store the HydroSeeder
®
with all slurry valve handles in the open position. To prevent
damage from freezing, it is advisable to remove all slurry valves and store in a heated
area.
4. Pour 1 quart (0.95 L) of mineral oil or environmentally safe lubricant into the pump housing
and spin pump by hand to prevent rust in the pump. Remove drain plug.
5. Chip and steel brush any interior rust spots in the slurry-tank and touch up with paint.
See Number 3 in IV. MAINTENANCE of the HYDROSEEDER® SAFETY SUMMARY
SECTION.
6. Lubricate all fittings.
7. Check anti freeze in radiator.
8. Lubricate equipment again just prior to putting into operation after having been in storage.
10. Change hydraulic oil and filter. (500 hours)
11. Disconnect battery cables. In cold weather, remove battery and store it in a safe, warm
place.
12. Add fuel stabilizer to fuel tank.
Содержание HydroSeeder T170 MB
Страница 4: ......
Страница 30: ...24 DISPLAY LIST SINGLE DATA FORMAT DUAL DATA FORMAT...
Страница 50: ...44 12 6 1 5 3 4 3 7 11 8 2 9 10 Figure 9 Lubrication and Adjustment Points...
Страница 57: ...51 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 58: ...52 8 ft 10 in 269 cm 16 ft 8 in 508 cm 7 ft 9 in 236 cm...
Страница 60: ...54 THIS PAGE LEFT BLANK INTENTIONALLY...
Страница 66: ...T170 MB0521 Rev B WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 60 1 3 4 5 2 6 7 8 2...
Страница 72: ...T170 MB0521 Rev B WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 66 1 2 3 4 5 6 7 8 9 10 11...