background image

 

Connect to cold water supply 

1.

 

Cut into existing 15mm copper pipe. Add the 15mm compression 

tee fitting.

 

2. Using the 

grey ¾” x 3/8” PF fitting, screw this on to the male thread 

of the compression tee piece. Ensure all fittings are secure. 

(

The ¾” x 3/8” PF fitting can also be connected to garden tap if you 

prefer to connect the unit this way) 

Install drain clamp 

Determine location for drain clamp based 
on plumbing layout. Drain should be 
installed 

above 

the trap on either the 

horizontal or vertical tailpiece, it should be 
mounted as low as possible to avoid 
draining noise.  

3

. (1/8” Optional) using a 1/8” drill bit, drill a 

1/8”  hole  into  one  side  of  the  drainpipe. 
Then to enlarge the hole, use a ¼” drill bit. 

4. Taking the side of the drain clamp with the QC fitting, stick the self-
adhesive  sponge  provided  to  the  inside  of  the  drain  clamp  (remove 
centre piece of sponge beforehand). Place one half of the plastic clamp 
on either side of the drainpipe with, and clamp loosely using the nuts 
and bolts included. 

5. Align hole on drain clamp with drilled hole. A drill bit (or pen/pencil) 
may be used to help with alignment. Once aligned, tighten clamp with 
Phillips screwdriver. 

Avoid over-tightening clamp. 

6. Determine length of tubing needed for connection from RO system 
to drain clamp and cut to length. Push tubing into fitting on clamp and 
insert blue collet clip under collet. Pull the tubing back to check seal is 
secure. 

 

 

 

 

Содержание RO400-E2

Страница 1: ...01704 807600 www finerfilters co uk enquiries finerfilters co uk Reverse Osmosis System Installation and Maintenance Manual For System RO400 E2...

Страница 2: ...1 Contents 1 General Information Page 2 2 Unit Information Page 3 3 Preparation Page 4 4 Installation Page 5 5 Maintenance Page 10 6 Replacement Filters Page 11 7 Troubleshooting Page 13...

Страница 3: ...f foreign particles colloid organic substances heavy metals soluble solids bacteria viruses pyrogen nitrate microorganisms hormones fluoride and other harmful impurities It only retains water molecule...

Страница 4: ...2 Inlet water temperature 4 42 C 4 Pre treatment filters total water output 1000L 5 Water supply tap or ground water TDS 1000ppm 6 Operating bar pressure 3 Bar 45PSI or more Optimal pressure to recei...

Страница 5: ...cut to length through each stage of installation The inlet to the unit is the larger pipe which is 3 8 size and the smaller is the output tubing which is size Mark 1 WHITE stopper Cold water supply to...

Страница 6: ...TRAIGHT WITH NO JAGGED EDGES Fitting type 1 Quick Connect QC fitting How to connect See Fig 3 Remove collet clip insert tubing into fitting until it locks Gently pull tubing back to ensure fit is secu...

Страница 7: ...ll prefer to gather the water directly into a clean bucket 1 Determine location for tap cut tubing to length see fig 1 and 2 and install tap using the diagram below or using white fitting provided Dia...

Страница 8: ...bit drill a 1 8 hole into one side of the drainpipe Then to enlarge the hole use a drill bit 4 Taking the side of the drain clamp with the QC fitting stick the self adhesive sponge provided to the in...

Страница 9: ...bing into the connections listed below Mark 1 WHITE stopper Cold water supply to RO system Mark 2 BLACK stopper Wastewater to drain Mark 3 YELLOW stopper Do not remove unless you are connecting to a p...

Страница 10: ...and check the fitting tubing where the leak was found Also see our troubleshooting section at the back of the manual Once the issue is resolved start process again Turn off the mains water by the isol...

Страница 11: ...arly can also prolong the life of your RO system The table below shows how often it is recommended to replace each filter stage in your system This is dependent upon water quality water hardness parti...

Страница 12: ...sed through our website www finerfilters co uk or call us on 01704 807600 Replacing your filters Filters only not membrane Please have some towels and cloths ready as some water will escape from the u...

Страница 13: ...rom the packaging and screw the fittings back in place Ensure the filter is the correct way by the flow arrow Put filter back in place and re insert the tubing and collet clip and pull back to ensure...

Страница 14: ...ush valve is closed Slow flow 1 Pre or post filter clogged 2 Low Water Pressure 3 Clogged Membrane 1 Check replace pre or post filter 2 Booster Pump required 3 Open L1 flush valve and carry out system...

Страница 15: ...sure O ring is in groove and lubricated Membrane housing see insert membrane on pg 10 Cloudy milky water 1 Defective membrane 2 New filters or membrane 1 Replace if TDS reading is below 85 2 Flush sys...

Отзывы: