5-1. MIN/MAX Mode
Press the button momentarily to activate MIN/MAX(Record) mode with LCD
annunciators MAX MIN AV G turned on. Press this butt on momentarily to read
throughout the maximum(MAX), Minimum(MIN), and Average(AVG) readings in the
primary display. Press this button for more than 1 second to exit MIN/MAX (Record)
mode.
With the Autoranging MIN/MAX (Record) mode, you can easily track intermittent
signals, capture turn on/ turn off surges, and monitor line voltage changes over a
much wider dynamic rage with the best resolution. It surpasses manual ranging
recording which is apt to be overflowed or to have insufficient resolution. The meter
f eatures a fast sampling speed of 50 ms for MAX, MIN and AVG readings. The
faster the sampling speed, the more accurate the measurements will be. The true
average (AVG) feature calculates all readings continually taken over time. The
Auto-Power-Off feature will be automatically disabled in this mode.
5-2. 1 ms Peak Mode
Press the (1 ms Peak) button
f or more t han 1 second to activat e 1
ms Peak mode with LCD annunciators
1 ms MAX MIN turned on. The met er
def ault s at 1 ms MAX (positive peak
value reading) mode.
P ress the menukey 2 momentarily to
select 1 ms MIN (negative peak value
reading) mode.
Press the menukey 4 ( on
menu screen) to exit 1 ms Peak mode.
With 1 ms Peak mode, transient signal
peak voltage as short as 1 ms can be
captured.
5. ADVANCED FEATURES
5-3. Manual and Auto Ranging
Press the button momentarily to select manual ranging, and the meter will
remain in the range it was wit h LCD annunciator t urned off. Press this butt on
momentarily again t o step through the ranges. P ress this button for more than 1
second to resume autoranging.
In Dwell( ) function, press this (Cylinder) button momentarily to display
the cylinder setting on the secondary display. Default is
CL
4 (4 Cylinder). Press this
button momentarily again to select the number of cylinders from 1 through 12 (1, 2,
3, 4, 5, 6, 8, 10, and 12 cylinders) to match the engine under test.
NOTE: The secondary display defaul ts at
rpm in the , , and Hz
function.
The selected cylinder setting or RPM setting is maintained until
the meter is turned off.
5-4. Trigger Level and +/- Trigger Slope Selection
This feature is available for RPM, Dwell, ms-Pulse, or Duty measurement function.
The meter is set at selected trigger level as power up default in individual function
as follows :
However, car signal levels under test may vary due to aging of component s,
abnormal conditions, and each car manufact urer’s diff erent design. Therefore,
positive and/or negative 4 selectable trigger levels, which are carefully designed
and tested to cover all the extreme conditions, are available in these functions to
provide more flexibility to cope with your applications.
If your reading is unstable, select lower sensitivities (higher trigger level number) by
pressing the button momentarily. If your reading shows zero, select higher
sensitivities (lower trigger level number).
FUNCTION
RPM
Dwell, ms-Plulse, Duty
DEFAULT TRIGGER LEVEL
+ TRIG
– TRIG