background image

Observe the instructions listed below in operating this equipment to
avoid a fatal accident that may result in “electric shock“ and
“injuries.“

1. Do not use the tester in a power line exceeding 3.6 kVA.
2.

Pay special attention when measuring the voltage of AC33V(46.7peak),
DC70V or more to avoid injury.

3. Do not input signals that exceed the maximum rated input value.
4. Do not measure lines (such as motor lines) where inductive

voltages and surge voltages will occur as they may exceed the
maximum overload input value.

5. Do not operate the meter when the main body or test lead is

damaged or broken.

6. Do not use the tester with its case removed.
7. Do not change function during measurement.
8. Confirm the function every time when making measurement.
9. Do not use the tester with wet hand.

10. Be sure to use the designated test leads.
11. Do not attempt repair or modification, except for replacement of

the built-in battery.

12.

Be sure to carry out startup checks and inspections at least once a year.

13. This tester is for indoor use.

− 2 −

[1] Safety Information

Prior to use, read the following precautions carefully

Thank you for selecting a SANWA Analog Multitester AP33.
Prior to use, please read this instruction manual thoroughly to ensure
correct and safe use. After reading it, please keep it together with the
tester in a safe place for future reference.
Be sure to observe instructions marked with WARNING and CAUTION
to avoid accidents involving “shock hazards“, “injuries and damages.“

1-1 Description of Warning Symbols

Symbols and their meaning used on product and Instruction Manual.

:Indicates very important instructions for safe use.
:WARNING identifies instructions to CAUTION identifies 

information to avoid unsafe operation that may result in damages 
to the equipment.

:AC

:DC

:Resistance

:Positive

:Negative

:Double insulation or reinforced insulation

1-2 Warning Instructions for Safe Use

WARNING

− 3 −

1-3 Maximum Overload Protective Input

※1 

(Tested by applying load 9 times for 0.5 sec. and once for 5 sec. every about 

one minute.)

Function(Range)

Input
Terminal 

*1 Max. Overload Protective Input

DCV

500V

AC

DC 550V or peak max770V

250V/50V

AC

DC 500V or peak max700V

10V

AC

DC 250V or peak max350V

ACV

500V

AC

DC 550V or peak max770V

250V/50V

AC

DC 500V or peak max700V

DCA

250mA

AC

DC 10V or peak max14V

25mA

AC

DC 3V or peak max4.2V

Ω

×

1k

AC

DC 135V or peak max189V

×

10

AC

DC 15V or peak max21V

BATT.

9V/1.5V

AC

DC 35V or peak max49V

,

1-4 General Handling Precautions
1. Vibration:

Do not place the tester on vehicles such as motorcycles as it is exposed to
frequent vibration that causes a tester failure.

2. Environment:

Do not store the tester for long hours in places where it is exposed to direct sunlight,
high temperature (over 60

), high humidity (over 85%) or where condensation occurs.

3. Electrification:

The tester cover has been treated by antistatic coating.  Do not rub it with cloth strongly.

4. Maintenance:

When servicing the tester, wipe off dust and dirt lightly with a brush or cloth.
Do not use a solvent such as thinner and alcohol.

5. Caution:

Do not use the tester near places where strong electromagnetic waves
are generated or charged substances are present.

[2] Application and Features
2-1 Application

This is a pocket type portable analog multitester designed for measuring small-
capacity power lines.
This tester is suitable for measuring voltages and testing continuity of household
appliances and measuring voltages of electric light circuits, batteries, etc.

2-2 Features

A pocket size AMT with a built-in shock absorbing rubber.

[3] Panel Description

1. Protector
2. Analog display
3. 0 

Ω

adjuster

4. Resistance range
5. Battery test range
6. DC current renge
7. Test leads
8. (OFF)

1

2

3

4
5

6

7

8

9

10

11

12

13

9. Range selector

10. DC voltage range
11. AC voltage range
12. Meter 0-position adjuster
13.Test pins

− 4 −

[4] Measuring Procedure
4-1 Startup Check

Turn the 0-position adjuster to align the pointer with the 0 position on
the left end of the analog display.

WARNING

1. Do not use the tester when its body or test leads are

damaged or broken.

2. Make sure that the test leads are not cut.

S t a r t

Body and test 

leads condition?

Broken

Yes

Not broken

Check  continuity  of 
test leads and fuse.

Stop using tester and 
have it repaired.

Proceed to 
measurement.

①Turn range selector 

to Ω range.

Replace fuse or battery 
and repeat from ①.

②Short red and black 

test leads. 

Does pointer move 

to right largely?

No

4-2 DC Voltage (DC V) Measurement

Turn the range selector to a desired range of “DC V”.

Connect the black test pin to “

“ (negative, ground) of a circuit to 

measure and the red test pin to “

” (positive, measuring point).

Connect the tester in parallel

with the power supply (circuit).

Read the measured value on the 
DC V scale (black).

An example of measurement:

Voltages of commercial dry cells,
car batteries and button batteries.

Car

battery

4-3 AC Voltage (AC V) Measurement

Turn the range selector to a desired 
range of “AC V”.

Regardless of 

/

polarity, connect 

the test pins to a circuit to measure.

Connect the tester in parallel

with the power supply.

Read the measured value on the 
AC V scale (red).

An example of measurement:

Voltages of household outlets

WARNING

A measurement error will become larger when a voltage of waveform
other than sine wave AC is measured.

− 5 −

4-4 DC Current (DC mA) Measurement

Turn the range selector to a 
desired range of “DC mA”.

Turn off the power switch of a 
circuit to measure to isolate the 
object to be measured.

Connect the black test pin to the 
negative side of the circuit to 
measure and the red test pin to 
the positive side.

WARNING: 

Connect the tester in series with the circuit.

Read the measured value on the mA scale (black).

WARNING: 

Never apply voltage.

B

a

t

t

e

r

y

4-5 Resistance (

Ω

) Measurement

Turn the range selector to a 
desired range of “

Ω

”.  Short the 

red and black test pins and then 
adjust 0 

Ω

with the 0 

Ω

adjuster.

Connect the test pins to a resistor 
or circuit to measure.

Read the measured value on the 
OHMS scale (green).

An example of measurement: Check of wiring of resistors and cords.

WARNING: 

Never attempt to measure resistance of lines with voltage.

Resistor

4-6 Battery Load Voltage (BATT) Measurement

A battery of 1.5 V and 9 V can be tested.

Connect the red test pin to the 

positive side of the battery 

and the black test pin to the 
negative side.

Judge the indication on the BAD? 
GOOD scale.

CAUTION: 

The button battery cannot

be measured.

CAUTION: 

To prevent battery discharge, complete measurement quickly.

Battery

[5] Maintenance

WARNING

1. This section is very important for safety. Read and understand

the following instruction fully and maintain properly.

2. The instrument must be calibrated and inspected once a year to

maintain the safety and accuracy.

− 6 −

[6] After-Sales Service
6-1 Warranty and Provision

Sanwa offers comprehensive warranty services to its end-users and
to its product resellers. Under Sanwa's general warranty policy, each
instrument is warranted to be free from defects in workmanship or
material under normal use for the period of one (1) year from the date
of purchase.
This warranty policy is valid within the country of purchase only, and
applied only to the product purchased from Sanwa authorized agent or
distributor.
Sanwa reserves the right to inspect all warranty claims to determine
the extent to which the warranty policy shall apply. This warranty shall
not apply to fuses, disposables batteries, or any product or parts,
which have been subject to one of the following causes:
1. A failure due to improper handling or use that deviates from the 

instruction manual.

1. The body is sensitive to volatile solvents. Do not wipe it with

thinner and alcohol.

2. The body is sensitive to heat. Do not place the tester near heat-

generating sources.

3. Do not keep the tester in places where the tester may be exposed

to vibration or where there is a risk of falling down.

4.

Do not keep the tester in places where it is exposed to direct sunlight,
high temperature, low temperature, high humidity or condensation.

5. When the tester is not used for an extensive period of time, be

sure to remove internal batteries from it.

5-3 Storage

CAUTION

5-4 Replacement of the Battery and Fuse

Factory-preinstalled built-in battery
A battery for monitoring is preinstalled before shipping, therefore it may run
down sooner than the battery life specified in the instruction manual.

The “battery for monitoring” is a battery to inspect the functions and 

specifications of the product.

Unfasten two screws on the backside of the body using a 
screwdriver to remove the rear case.

Remove the battery or fuse and replace it with new ones.
Battery: R03 (UM-4, AAA), 1.5 V
Fuse: 

φ

5 x 20, 0.5 A/250 V

Put the rear case and fasten the screws.

5-1 Maintenance and Inspection

1)

Check the appearance for any damage caused by a drop or for any other reason.

2) 

Check the test lead for any damage or break.

If the tester is in one of the above conditions, stop using it and have it repaired.

5-2 Calibration and Inspection

Contact the authorized agent of Sanwa Electric Instrument Co., Ltd. for
calibration and inspection of the equipment.

− 7 −

2. A failure due to inadequate repair or modification by people other 

than Sanwa service personnel.

3. A failure due to causes not attributable to this product such as fire, 

flood and other natural disaster.

4. Non-operation due to a discharged battery.

5. A failure or damage due to transportation, relocation or dropping 

after the purchase.

6-2 Repair

Customers are asked to provide the following information when
requesting services: 

1. Customer name, address, and contact information

2. Description of problem

3. Description of product configuration

4. Model Number

5. Product Serial Number

6. Proof of Date-of-Purchase

7. Where you purchased the product

1) Prior to requesting repair, please check the following:

Capacity of the built-in battery, polarity of installation and 
discontinuity of the test leads.

2) Repair during the warranty period:

The failed meter will be repaired in accordance with the conditions 
stipulated in 6-1 Warranty and Provision.

3)

Repair after the warranty period has expired:

In some cases, repair and transportation cost may become higher 
than the price of the product. Please contact Sanwa authorized 
agent / service provider in advance.
The minimum retention period of service functional parts is 6 years
after the discontinuation of manufacture. This retention period is 
the repair warranty period. Please note, however, if such 
functional parts become unavailable for reasons of discontinuation 
of manufacture, etc., the retention period may become shorter 
accordingly.

4) Precautions when sending the product to be repaired

To ensure the safety of the product during transportation, place
the product in a box that is larger than the product 5 times or more
in volume and fill cushion materials fully and then clearly mark
“Repair Product Enclosed” on the box surface.  The cost of
sending and returning the product shall be borne by the customer.

6-3 SANWA web site

http://www.sanwa-meter.co.jp
E-mail: [email protected]

− 8 −

[7] Specifications

Guaranteed accuracy range: 23℃ ±2℃, 75% RH max.

Measuring Range 

Accuracy

   DC voltage  10/50/250/500V(2kΩ/V) 
   AC voltage  50/250/500V(2kΩ/V) 
  DC current  25m/250mA 
  

Ω 

×10(5k) 

  Open voltage 

±3% of scale length 

  (OHMS)  ×1k(500k) 

       1.5V 

 

  BATT

 

1.5 V load approx 14 Ω 

− 

  

9 V load approx 420 Ω 

 

±5% of full scale

Item 
Meter 
Built-in fuse 
Built-in battery 
Operating temperature & 
humidity

Specifications 
Moving-coil, pivot type 
0.5 A / 250 V, φ5 × 20 mm fast acting fuse 
R03, 1.5V × 1 
5 −40℃, 80% RH or below, no condensation. 
80% RH (max.) at 5 〜 31℃ and linear decrease from 
80% RH to 50% RH at over 31℃ and up to 40℃. 
 

Storage temperature & Humidity 
Operating environment 
Dimensions 
Weight 
Standard accessory 
Safety standards 
 
 
EMC Directives 
 

−10 − 50℃, 70% RH MAX. No condensation. 
Max. 2000 m, Pollution degreeⅡ, indoor use 
126(H) × 87(W) × 30(D)mm 
Approx. 185 g 
Instruction manual 1 
IEC/EN 61010-1 : 01 and IEC/EN 61010-031 : 02 
Complies with AC/DC500V MAX CAT. Ⅱ 
Complies with AC/DC300V MAX CAT. Ⅲ 
EN 61326-1, EN 55011, EN 61000-3-2, 
EN 61000-3-3, EN 61000-4-2 and EN 61000-4-3 
 

The specifications are subject to change without notice.

AP33

MULTITESTER

INSTRUCTION MANUAL

Dempa Bldg, 4-4 Sotokanda 2-Chome, Chiyoda-Ku,Tokyo, JAPAN

SANWA ELECTRIC INSTRUMENT CO., LTD.

05.

11