7.1 Error messages / ERROR
If the complete display is flashing, an error occurred.
The error code can be queried on level d under the parameter Err.
The following error codes are possible:
Connected acceleration sensor is defective or not connected
(in
regular
operation
only)
Overload shutdown, output power exceeded, e.g., incorrect frequency
setting
or
air
gap
too
wide
Critical temperature exceeded on the power output stage
Mains voltage lies outside of the standard voltage ranges 90-130 V~
and
190-250
V~
Nominal control value cannot be reached
Short-circuit shutdown (defective magnet, ground fault, defective cable)
Data loss in the EEPROM
Processor
communication
error
Special error:
Keypad query error
In the case of frequently occurring error messages not described in this section, please contact the