6
FIGURE 1:
1. Graphic display:
The 5,7’’ colour screen displays different
screens, according to the welding mode or
settings. In weld mode the display is divided
into five principal:
Part 1:
Machine status
Part 2:
Meaning of the active buttons
(buttons 2, 3, 4, 5,6 di fig.1)
Part 3:
Size values set
Part 4:
Type of process selected
Part 5:
Indicates the values that can be set
for the various welding settings (to change
the values select using switch 10 and
confirm the selection by pressing the same
switch; the value will be highlighted in a
contrasting colour. The values can be
changed by turning the switch, to confirm
the new value press the switch again. 10).
Highlighted value: Indicates the parameter
that is being changed using switch 10.
DISPLAYS:
- When the screen comes on, the Fimer logo
will appear and the Firmware revisions will load.
CONTROL BUTTONS:
(2, 3, 4, 5,6 in fig.1)
Each control button is associated with a
specific function shown on the display.
7. SD slot:
this slot, covered with a rubber
cap, contains the SD-Card provided with the
machine; without the card, the machine will
be inactive and a warning message will
appear on the screen.
8. USB port:
for technical assistance only.
9. Switch for adjusting the principal
welding settings:
This switch is used to
set the principal welding parameters:
MMA/TIG Welding; set the welding current
11. EUROCONNECTOR (SEPARATED TROLLEY):
quick connector for welding torch. This connector is
used to supply welding gas to the torch, the electrical
contacts of the torch button and the welding current.
12. TIG gas Outlet
13.
Connector for remote control of the current.
14. Front inlet “-”:
hold negative
MMA Mode:
Ground clamp
TIG Mode:
TIG Torch
MIG Mode with gaz:
Ground clamp
MIG Mode without gaz:
Ground clamp
15. Front inlet “+”:
hold positive.
MMA Mode:
Electrode holder
TIG Mode:
Ground clamp
MIG Mode with gaz:
Not used
MIG Mode without gaz:
Not used
FIGURE 2:
16. ON-OFF switch:
turns the machine on
and off.
17. POWER INPUT CABLE:
Connect to the
power supply.
18. CONTROL UNIT CONNECTOR
(OPTION)
19. GAS TUBE CONNECTOR:
This must be
connected to pressure regulator on the
cylinder.
FIGURE 3:
20. WIRE SPOOL SUPPORT
21. WIRE FEEDER SYSTEM:
see figure 3A
for a more detailed image.
22. INLET OF THE WIRE FEEDER MOTOR
23. WIRE TENSION REGULATOR:
Adjusts
the tension of the welding wire.
24. WIREFEEDER SPOOLS
Part 1
Part 2
Part 3
Part 4
Part 5
20
21
24
23
23
22
Fig. 3A
Содержание King 320
Страница 2: ......
Страница 3: ...KING 320 ...
Страница 4: ...TARGA DATI NOMINAL DATA LEISTUNGSCHILDER PLAQUE DONÉES PLACA DE CARACTERÌSTICAS ...
Страница 34: ...2 WARNING SYMBOLS ...
Страница 35: ...3 ...
Страница 36: ...4 ...
Страница 62: ...2 VERWENDETE SYMBOLE ...
Страница 63: ...3 ...
Страница 64: ...4 ...
Страница 90: ...2 SYMBOLES UTILISÉS ...
Страница 91: ...3 ...
Страница 92: ...4 ...
Страница 118: ...2 SÌMBOLOS UTILIZADOS ...
Страница 119: ...3 ...
Страница 120: ...4 ...
Страница 145: ...NOTE ...
Страница 146: ...NOTE ...
Страница 147: ......
Страница 148: ......