AC Power Check
53
Document 45277-0805
3.
Verify the voltage at XFMR3-P1 is 120 VAC.
4.
Turn CB8 OFF and reconnect the connector.
Testing CB9 Circuit.
1.
Disconnect MTR1-P1 (Star Motor Controller)
2.
Turn CB9 ON
3.
Verify that the voltage at MTR1-P1 is 120VAC.
4.
Turn CB9 OFF.
Testing CB10 Circuit.
1.
Remove MTR2-P1 (Takeaway Power)
2.
Turn CB10 ON.
3.
Verify that the voltage at MTR2-P1 is 120VAC.
4.
Turn CB10 OFF and reconnect MTR2-P1.
Testing CB11 Circuit
1.
Turn CB11 ON.
2.
Check PL1 - J1(Utility 2, Euro Panel) for 220VAC
3.
Check PD1-J2 for 220VAC
4.
Turn off CB11.
Testing CB12 Circuit
Make sure the Air Conditioning power has a connector or tape
on the ends before this test.
1.
Disconnect Air Conditioner connector
2.
Disconnect XFMR2-P1 (24V XFMR).
3.
Turn CB12 ON.
4.
Measure Air conditioner plg for 220VAC