l
RAZL-2 CO is set up as a skin column.
l
Shelly Relay is factory-set. On your computer or smartphone, open the Wi-Fi settings and connect
to the WiFi network created by Shelly, e.B. shelly1-35FA58.
l
Enter 192.168.33.1 in your browser's address field to load the Shelly web interface.
l
Select the WiFi Settings from the settings menu and activate the WiFi Client Mode (CM) operating
mode. Enter the WLAN data of the main column as the SSID and RAZL-2 CO password.
l
In the IP settings, select static IP and enter 10.1.10.2. If you use multiple relays, adjust the IP. The
available range is 10.1.10.2 to 10.1.10.99. Save the settings, the relay will restart automatically. If
you have problems with setting up the relay, please refer to the Shelly Relay manual.
l
Connect to the Wi-Fi RAZL-2 CO network and enter http://razl.lan in your browser's address box.
l
Activate the configuration mode by pressing the lock icon. Now, in the overview menu, switch to
the External Actuators category. Press the Add New Actuator button here. Enter the following data
in the dialog and confirm the entries with the Save button.
Name
Custom name of the actuator
Event type
System status changed
Event
Maximum number of people reached
Url of the actuator
http://10.1.10.2/relay/0?turn='CONDITION-
RESULT'
Request Header
Leave unchanged
HTTP request method
Get
Event Rule
Send if the event type is consistent with
Содержание RAZL-2 CO
Страница 16: ...l Lizenzverwaltung l Software Update ...
Страница 21: ...l Um die geänderten Einstellungen zu übernehmen betätigen Sie das Feld Speichern ...
Страница 25: ...l Um den aktuellen Status zu ändern betätigen Sie die Schaltfläche Gerät deaktivieren Gerät akti vieren ...
Страница 31: ...Erweiterungsmöglichkeiten Externe Aktoren auf Seite37 Externe Bildschirme auf Seite34 REST API auf Seite35 ...
Страница 63: ...l To accept the changed settings click on the Save field ...
Страница 72: ...Extension possibilities External actuators on page77 External screens on page74 REST API on page75 ...