Installation Instructions
WARNING: Installation must be carried out by a qualified person
This section is provided for information purpose only and may vary depending on your location/
regulations
/ available space for installation
1.
Pre-Requirements
Needed equipment for installation of heat pump:
Suitable power supply cable for unit’s power. Usually 12-2+Ground protected by flexible conduit
A by-pass kit ( 3 way valve) , PVC pipe and fittings, Pipe cleaner/ primer, Medium Bodied Glue
Electrical tools, and a ,multimeter
A service disconnect or timer within 6 feet of the heater
An equipment pad, 16” x 32” x 4” thick or 2 pieces of concrete blocks, 16 x 16 x 4 inches each
2.
Location
Please comply with the following rules about heat pump location choosing.
1.
Make sure the heater is not directly below the roof drains, such as gutter drain, or eaves.
2.
Be sure that the heater does not submerge in water in heavy rain.
3.
Be sure to install the drain adapters into the heaters, and attach the hose to direct the
condensation water. Heater will produce gallons of water from condensation, every day.
4.
Confirm the unit is under well-ventilated conditions; fan discharge grill vent is not blocked ( Fan
blows outwards.)
5.
Keep at least 12 inches of clearance on the two short sides and the long radiator side.
6.
Keep at least 3 feet of clearance on the fan side of the heater.
7.
Keep the unit as far as possible away from children's reach and within 25 feet of the pool.