ELECTRICAL CONNECTIONS
Power Supply Wires Size
Model
Power Supply Wires
Power Supply
Cable Diameter
Specification
Fh 270
208-240V/60Hz
3×4.0mm (3×0.157inch)
AWG 12
WARNING: Power supply of heat pump must be disconnected before any operation.
➢
Step 1: Detach front panel by a screwdriver.
➢
Step 2: Insert cable into heat pump electrical connector port. This port is designed for
outdoor SO cords (waterproof flexible cords.) If using a flexible conduit, simply remove
the adapter, and install conduit adapter.
➢
Step 3: Connect power supply cable to terminal block according to the diagram below.
➢
FH 270 does NOT have a NEUTRAL connection Therefore, Do NOT use a GFCI breaker.
➢
FH 270 requires equipotential bonding. Please connect an #8 AWG bare copper wire to a
ground rod. This is required for safety and corrosion prevention of the heaters metal
chassis.
V-2105 Fibropool Co LLC, Ms USA
Содержание FH 270
Страница 1: ...FIBROPOOL FH 270 POOL HEAT PUMP Installation Instruction Manual V 2105 Fibropool Co LLC Ms USA ...
Страница 4: ...1 Unit Dimensions Model Fh 270 Unit in V 2105 Fibropool Co LLC Ms USA ...
Страница 17: ...V 2105 Fibropool Co LLC Ms USA ...
Страница 18: ...V 2105 Fibropool Co LLC Ms USA ...