BELOW ARE COMMON QUESTIONS ASKED

To resolve a problem, we need to identify whether it is a mechanical problem, or performance.  

POOL NOT HEATING:

In and out difference too small

:  Either the air humidity is too low, or the pool pump is 

pushing too hard. Difference 0-4 degrees accepted. Higher the humidity ( 80% or higher), 
higher the difference. 

i

nitial heating takes time

. Allow a few days for the water to heat up, while leaving the pool 

pump and heater on 24-7.  And cover the pool with any type of cover.

Heater is not working: 

 there are 3 basic indicators of the heaters operation. 1- heater 

blowing cold air 2- compressor pressure goes up by about 0.5 MPA 3- heater dripping water 
from the condensation lines after 10-15 minutes. If any of these conditions are observed, the
heater is working. The problem is performance, not functionality

Heater is not leaking water from the bottom: 

Heat pumps will create quite a bit 

condensation, which will drain from the bottom of the heater.

The air is too dry:

 Pool heat pumps are optimized for 80% humidity. If the humidity is much 

less, best thing is to install a set of micron misters. A set can be purchased for about 20-30 
dollars from hardware stores. Which screws into the garden hose and sprays mist . Place 
the heads near the coils, this way the incoming air will draw moisture into the heater coils 
and heat exchange rate will increase, thus resuting in better output 

Pool pump's timer setting is too short: 

Pool heaters need pool pumps circulation. If the 

pump doesnt run long enough, neither will the heater. Please adjust the timer settings on 
your pump or remove the timer for heating.

The fan is not coming on, the pressure is not going up on the pressure gauge: 

When 

the thermostat calls for heat, the fan will come on within 4 minutes, and within 45 seconds, 
the compressor will kick in. If this doesnt happen, and the pool water temperature is much 
lower than the desired temperature, there is a mechanical issue of an error message on the 
screen. Be sure that there is no error messages on the screen. This may require a phone 
call to us at Fibropool Co.  1.228.313.7874

Pool is too big for the heater, for your climate zone: 

 There is not much can be done, 

except adding a second heater into the system.

Air is too cold:

 Heat pumps absorb heat from the air. If the air too cold- below 60F, the 

performance will be very little. Your only option is to wait for warmer weather. 

HEATER  IS GIVING WATER FLOW ERROR (PL)

Pool pump is OFF

Pool pump is really weak

Pool filter is dirty

Plumbing is connected backwards, cold water is connected to top

By pass valve is set incorrectly, not allowing water to flow thru the heater.

HEATER IS VIBRATING/ SHAKING HEAVILY

Loose or broken Fan blade

NO DISPLAY

Digital display is damaged. This happens mostly if the protective cover is broken or missing, making the 
controller NOT weather proof. 

The incoming power is not 220 volts. Reading between L1 and L2 should be between 208-240 volts. 

Motherboard's fuse is blown.

V-2105 Fibropool Co LLC, Ms USA

Содержание FH 270

Страница 1: ...FIBROPOOL FH 270 POOL HEAT PUMP Installation Instruction Manual V 2105 Fibropool Co LLC Ms USA ...

Страница 2: ...bing WATER AND ELECTRICITY DONT MIX PLEASE USE ALL PRECAUTIONS AND DO NOT SHORT CUT ANY SAFETY PROCEDURES Do not install this heater in an enclosed room Without adequate air supply the heater will not function well If the unit was installed in a closed area or limited space please consider the size of room and ventilation to prevent suffocation caused by refrigerant leakage Be sure to Install a BO...

Страница 3: ...eat exchanger Titanium tube heat exchanger Water flow gpm 33 GPM Net dimension LxWxH inch 37 x 14 x 32 Packing dimension LxWxH inch 41 x 17 x 33 Net weight lbs 146 lbs Packing weight lbs 196 Noise level dB A 47 Water proof level IPX4 Water pipe connection PVC Sch 40 1 1 2 Inlet Outlet The technical specification of our heat pumps is provided for information purpose only We reserve the right to mak...

Страница 4: ...1 Unit Dimensions Model Fh 270 Unit in V 2105 Fibropool Co LLC Ms USA ...

Страница 5: ... switch 18 Silencer cotton 3 Stand pillar 11 Titanium heat exchanger 19 Motor 4 Protection net 1 12 Right plate 20 Motor support 5 Protection net 2 13 Controller box 6 Evaporator 14 Handle 7 Electrical box 15 Cooper pipe component 8 Top cover 16 Compressor V 2105 Fibropool Co LLC Ms USA ...

Страница 6: ... 16 x 16 x 4 inches each 2 Location Please comply with the following rules about heat pump location choosing 1 Make sure the heater is not directly below the roof drains such as gutter drain or eaves 2 Be sure that the heater does not submerge in water in heavy rain 3 Be sure to install the drain adapters into the heaters and attach the hose to direct the condensation water Heater will produce gal...

Страница 7: ...should be installed If The heat pump is connected to a filtration circuit with a by pass valve The bypass valve should be partially opened throttled while all the other valves should be completely opened We suggest to open bypass 50 then adjust until the lowest volume of water going through the heater but no error messages EE 3 PL EE1 are present This will give enough water to the heater and not r...

Страница 8: ...1 Installation of a Single Heater 2 Parallel Installation for 2 Units Throttled by pas valve 50 open V 2105 Fibropool Co LLC Ms USA ...

Страница 9: ...fittings 6 If using flexible hoses be sure to tighten the clamps well 7 Be sure to check your fittings and glue them properly using pipe cleaner and a good grade Medium bodied glue 8 Heaters have heat exchanger coils therefore they increase back pressure 9 If your pool pump is larger than 1 horsepower you should use a bypass valve This will help water flow of your system to continueas original plu...

Страница 10: ...nector port This port is designed for outdoor SO cords waterproof flexible cords If using a flexible conduit simply remove the adapter and install conduit adapter Step 3 Connect power supply cable to terminal block according to the diagram below FH 270 does NOT have a NEUTRAL connection Therefore Do NOT use a GFCI breaker FH 270 requires equipotential bonding Please connect an 8 AWG bare copper wi...

Страница 11: ...purge from the system Turn on the heater Push the ON OFF button on the heater Making sure the SUNSHINE sign is on top ALLOW ABOUT 5 MINUTES FOR THE FAN TO START BLOWING COLD AIR CONDENSATE WATER TO START DRIPPING This is the indication of the heater working If all is well leave your heater running Your heater will only be on while your pump is ON In and out temperatures maybe very close or even th...

Страница 12: ...ET key Press this key to enter the fault query state and then press this key to query other fault displays in the current state Press and hold SET key to enter parameter state then press MODE key to enter the setting You can set the parameters by pressing key press SET key to set other parameters exit the parameter setting state automatically if there is no operation within 5 seconds FOR A HOMEOWN...

Страница 13: ...ature Unvalid 10 1 N A 11 3 20MIN 15 N A 12 Second anti freezing mode 1 fixed 13 Heat Cool Mode Selection 1 Adjustable 14 High pressure switch 1 15 Low pressure switch 2 16 Water flow switch 1 17 Emergency switch 2 18 Electric heater over heat protection 19 Inlet water temp 9 99 20 Outlet water temp 9 99 21 Coil temp 9 99 0 no 1 yes X Temp Difference between compressor Start desired setting accura...

Страница 14: ...Pool pump s timer setting is too short Pool heaters need pool pumps circulation If the pump doesnt run long enough neither will the heater Please adjust the timer settings on your pump or remove the timer for heating The fan is not coming on the pressure is not going up on the pressure gauge When the thermostat calls for heat the fan will come on within 4 minutes and within 45 seconds the compress...

Страница 15: ...ck w ater temperature Replace motherboard Turn the heater off at the breaker for 45 seconds and restart Replace the Sensor Excessively LOW outlet w ater temp in cooling mode Low w ater flow rate Water inlet w ater temp too low Motherboard failure Turn the heater off at the breaker for 45 seconds and restart Check the w ater flow through the heater Adjust the set temp to a higher level Replace moth...

Страница 16: ...rs in the winter After the unit is conditioned in winter season it is preferred to cover the unit with the special winter heat pump cover Please keep the coils clean by using Foaming air conditioner coil cleaner available at hardware stores Winterization If the unit is not running during winter months please disconnect power supply and pipes and let out drain water from unit by tilting the heater ...