Страница 1: ...FIBROPOOL FH 270 POOL HEAT PUMP Installation Instruction Manual V 2105 Fibropool Co LLC Ms USA ...

Страница 2: ...bing WATER AND ELECTRICITY DONT MIX PLEASE USE ALL PRECAUTIONS AND DO NOT SHORT CUT ANY SAFETY PROCEDURES Do not install this heater in an enclosed room Without adequate air supply the heater will not function well If the unit was installed in a closed area or limited space please consider the size of room and ventilation to prevent suffocation caused by refrigerant leakage Be sure to Install a BO...

Страница 3: ...eat exchanger Titanium tube heat exchanger Water flow gpm 33 GPM Net dimension LxWxH inch 37 x 14 x 32 Packing dimension LxWxH inch 41 x 17 x 33 Net weight lbs 146 lbs Packing weight lbs 196 Noise level dB A 47 Water proof level IPX4 Water pipe connection PVC Sch 40 1 1 2 Inlet Outlet The technical specification of our heat pumps is provided for information purpose only We reserve the right to mak...

Страница 4: ...1 Unit Dimensions Model Fh 270 Unit in V 2105 Fibropool Co LLC Ms USA ...

Страница 5: ... switch 18 Silencer cotton 3 Stand pillar 11 Titanium heat exchanger 19 Motor 4 Protection net 1 12 Right plate 20 Motor support 5 Protection net 2 13 Controller box 6 Evaporator 14 Handle 7 Electrical box 15 Cooper pipe component 8 Top cover 16 Compressor V 2105 Fibropool Co LLC Ms USA ...

Страница 6: ... 16 x 16 x 4 inches each 2 Location Please comply with the following rules about heat pump location choosing 1 Make sure the heater is not directly below the roof drains such as gutter drain or eaves 2 Be sure that the heater does not submerge in water in heavy rain 3 Be sure to install the drain adapters into the heaters and attach the hose to direct the condensation water Heater will produce gal...

Страница 7: ...should be installed If The heat pump is connected to a filtration circuit with a by pass valve The bypass valve should be partially opened throttled while all the other valves should be completely opened We suggest to open bypass 50 then adjust until the lowest volume of water going through the heater but no error messages EE 3 PL EE1 are present This will give enough water to the heater and not r...

Страница 8: ...1 Installation of a Single Heater 2 Parallel Installation for 2 Units Throttled by pas valve 50 open V 2105 Fibropool Co LLC Ms USA ...

Страница 9: ...fittings 6 If using flexible hoses be sure to tighten the clamps well 7 Be sure to check your fittings and glue them properly using pipe cleaner and a good grade Medium bodied glue 8 Heaters have heat exchanger coils therefore they increase back pressure 9 If your pool pump is larger than 1 horsepower you should use a bypass valve This will help water flow of your system to continueas original plu...

Страница 10: ...nector port This port is designed for outdoor SO cords waterproof flexible cords If using a flexible conduit simply remove the adapter and install conduit adapter Step 3 Connect power supply cable to terminal block according to the diagram below FH 270 does NOT have a NEUTRAL connection Therefore Do NOT use a GFCI breaker FH 270 requires equipotential bonding Please connect an 8 AWG bare copper wi...

Страница 11: ...purge from the system Turn on the heater Push the ON OFF button on the heater Making sure the SUNSHINE sign is on top ALLOW ABOUT 5 MINUTES FOR THE FAN TO START BLOWING COLD AIR CONDENSATE WATER TO START DRIPPING This is the indication of the heater working If all is well leave your heater running Your heater will only be on while your pump is ON In and out temperatures maybe very close or even th...

Страница 12: ...ET key Press this key to enter the fault query state and then press this key to query other fault displays in the current state Press and hold SET key to enter parameter state then press MODE key to enter the setting You can set the parameters by pressing key press SET key to set other parameters exit the parameter setting state automatically if there is no operation within 5 seconds FOR A HOMEOWN...

Страница 13: ...ature Unvalid 10 1 N A 11 3 20MIN 15 N A 12 Second anti freezing mode 1 fixed 13 Heat Cool Mode Selection 1 Adjustable 14 High pressure switch 1 15 Low pressure switch 2 16 Water flow switch 1 17 Emergency switch 2 18 Electric heater over heat protection 19 Inlet water temp 9 99 20 Outlet water temp 9 99 21 Coil temp 9 99 0 no 1 yes X Temp Difference between compressor Start desired setting accura...

Страница 14: ...Pool pump s timer setting is too short Pool heaters need pool pumps circulation If the pump doesnt run long enough neither will the heater Please adjust the timer settings on your pump or remove the timer for heating The fan is not coming on the pressure is not going up on the pressure gauge When the thermostat calls for heat the fan will come on within 4 minutes and within 45 seconds the compress...

Страница 15: ...ck w ater temperature Replace motherboard Turn the heater off at the breaker for 45 seconds and restart Replace the Sensor Excessively LOW outlet w ater temp in cooling mode Low w ater flow rate Water inlet w ater temp too low Motherboard failure Turn the heater off at the breaker for 45 seconds and restart Check the w ater flow through the heater Adjust the set temp to a higher level Replace moth...

Страница 16: ...rs in the winter After the unit is conditioned in winter season it is preferred to cover the unit with the special winter heat pump cover Please keep the coils clean by using Foaming air conditioner coil cleaner available at hardware stores Winterization If the unit is not running during winter months please disconnect power supply and pipes and let out drain water from unit by tilting the heater ...

Страница 17: ...V 2105 Fibropool Co LLC Ms USA ...

Страница 18: ...V 2105 Fibropool Co LLC Ms USA ...