Operating instructions WPM Gateway IoT
WPM Gateway Administration
9.4.2
Connection with an OPC UA Client
Connect an OPC UA Client with the WPM Gateway
On the WPM Gateway, an OPC UA server is executed, which supports the data exchange with
OPC UA clients.
Open view:
Main menu => Administration => Fieldbus
Fig. 9-5 Connection via Fieldbus interface
Ensure that the OPC UA Client is in the same network as the WPM Gateway.
The device description files for the OPC UA connection can be downloaded via the
Downloads
button.
•
Download OPC_UA_Gateway.xml
The data connection between an OPC UA Client and the WPM Gateway is generally established
via a secure connection. Therefore, the certificate of the OPC UA Client that will be connected
to the WPM Gateway must be uploaded to the WPM Gateway.
Upload OPC UA Client certificates to the Gateway
To obtain the OPC UA Client certificate, see the documentation for the OPC UA Client.
1) The certificate must be in DER format.
2) Drag and drop the DER file of the certificate into the upload area.
–
Alternatively, clicking in the upload area opens a file selection dialogue.
3) The certificate is automatically imported into the WPM Gateway.
OPC UA Client connection settings
1) Use the specified url in the OPC UA section to connect the OPC UA client to the WPM Gate-
way.
2) In the OPC UA Client, select Basic256SHA256 as Security Policy.
3) Authentication takes place via user name and password.
–
To create/change the user or password, see Chapter 6 "User management configura-
tion" on page 24.