![FIBARO FGT-001 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/fibaro/fgt-001/fgt-001_operating-manual_2286581019.webp)
19
Z
-
WAVE SPECIFICATION
#17: Z-Wave speci
fi
cation
Endpoint 1:
Generic Device Class: GENERIC_TYPE_THERMOSTAT
Speci
fi
c Device Class: SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
Description: represents
thermostatic head
, allows to set tempera-
ture, schedules and check its battery level.
Endpoint 2:
Generic Device Class: GENERIC_TYPE_SENSOR_MULTILEVEL
Speci
fi
c Device Class: SPECIFIC_TYPE_ROUTING_SENSOR_MULTILEVEL
Description: represents dedicated
temperature sensor
, allows to
check temperature and its battery level (if not paired reported tem-
perature and battery level are always 0).
Value
Action
0
Set OFF mode (unfreeze function)
99
Set HEAT mode (last set temperature)
255
Set MANUFACTURER SPECIFIC mode (valve fully opened)
Response to Basic Command Class:
Association Command Class:
The device supports only
“Lifeline”
association group that reports
the device status and allows for assigning single device only (main
controller by default).