Analog inputs reports and output change on input
change
This parameter defines minimal change (from the last reported) of
analog input voltage that results in sending new report and change
in the output value. Parameter is relevant only for analog inputs
(parameter 20, 21, 22 or 23 set to 0 or 1).
Parameter size
2B
Default value
5 (0.5V)
Available
values
0 - reporting on change disabled
1-100 (0.1-10V, 0.1V step)
64.
Analog inputs reports - periodic
This parameter defines reporting period of analog inputs value.
Periodical reports are independent from changes in value (param-
eter 63).
Parameter is relevant only for analog inputs (parameter 20, 21, 22
or 23 set to 0 or 1).
Parameter size
2B
Default value
0 (periodical reports disabled)
Available
values
0 – periodical reports disabled
30-32400 (30-32400s, 1s step)
65.
Energy reports - on change
This parameter determines the minimum change in consumed
energy that will result in sending new energy report to the main
controller. Energy reports are sent no often than every 30 seconds.
Parameter size
2B
Default value
10 (0.1 kWh)
Available
values
0 - reports are disabled
1-500 (0.01 - 5 kWh) - change in energy
66.
Energy reports - periodic
This parameter determines in what time intervals the periodic
energy reports are sent to the main controller. Periodic reports do
not depend of energy change (parameter 65)
Parameter size
2B
Default value
3600 (1h)
Available
values
0 - periodic reports are disabled
30-32400 (30-32400s) - report interval