confIguratIon
42.
Input 3 - sent scenes
This parameter defines which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
rameter 22 is set to 2, 3 or 4.
Actions can be summed up, e.g. 1+2+4+8=15 and entered as a val-
ue for the parameter.
Parameter size
1B
Default value
15
Available
values
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
43.
Input 4 - sent scenes
This parameter defines which actions result in sending scene ID
and attribute assigned to them. Parameter is relevant only if pa-
rameter 23 is set to 2, 3 or 4.
Actions can be summed up, e.g. 1+2+4+8=15 and entered as a val-
ue for the parameter.
Parameter size
1B
Default value
15
Available
values
1 – Key pressed 1 time
2 – Key pressed 2 times
4 – Key pressed 3 times
8 – Key hold down and key released
62.
Power reports - periodic
This parameter determines in what time intervals the periodic
power reports are sent to the main controller. Periodic reports do
not depend of power change (parameter 61).
Parameter size
2B
Default value
3600 (1h)
Available
values
0 - periodic reports are disabled
30-32400 (30-32400s) - report interval
Содержание FGRGBW-442