23
confIguratIon
31.
Alarm configuration - 2nd slot
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
significant bytes are set according to the official Z-Wave protocol
specification.
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size
4B
Default value
[0x05, 0xFF, 0x00, 0x00]
(Water Alarm, any notification, no action)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no reaction,
0x0X
– turn off selected chan-
nel,
0x1X
– turn on selected channel,
0x2X
– blink
selected channel,
0x3Y
– activate alarm sequence
32.
Alarm configuration - 3rd slot
This parameter determines to which alarm frames and how the
device should react. The parameters consist of 4 bytes, three most
significant bytes are set according to the official Z-Wave protocol
specification.
X – channels summarized: 1/2/3/4 channel are equal to values
1/2/4/8. Y – sequence number: 1-10 (parameter 157).
Parameter size
4B
Default value
[0x01, 0xFF, 0x00, 0x00]
(Smoke Alarm, any notification, no action)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no reaction,
0x0X
– turn off selected chan-
nel,
0x1X
– turn on selected channel,
0x2X
– blink
selected channel,
0x3Y
– activate alarm sequence