Brewing Problem 

Possible Cause 

Solution 

Spray head / brew basket drips either 

side or both 

 

MAJOR 

Cracked dispense tube/s 

(This problem starts out minor but 

gets steadily worse) 

-Replace both dispense tubes even if other side is not 

dripping  

 

Fill valve not sealing 

(Will drip even with power off.) 

-See next section - “Brewer won’t stop brewing”, “Bad or 

stuck fill valve”. 

Brewer won’t stop brewing

 

Dispense tube cracked  

-See “sprayhead drips MAJOR” above 

       (

not same as

 

high brew levels

Mechanical binding 

(brew handle stays down / brew light 

turns off at normal time) 

-Re-align the brew handle / brass sprayhead tower / and 

dispense tube into a straight line by moving brass tower 

 

Water pressure over 75psi 

-Place a water pressure regulator on the line and reduce to 

20-75 psi 

 

Dispense tube drive screw off. A 

2.5” screw that connects the handle 

to the dispense tube at the brass 

sprayhead tower. 

(handle returns up and brew lamp 

turns off but brewing continues) 

-Ensure that the drive screw is straight (can be straightened 

by hand while still in the brew handle) and reconnect to the 

dispense tube. The flange that the drive screw engages 

MUST be held flat against the brass sprayhead tower, 

without being able to back out. 

 

Water level probe bad or encrusted 

with lime. 

(causes brewer to continue filling hot 

water tank which will overflow into 

the brew baskets) 

-Clean lime build up on the probe tip 

and/or tank wall. (Holding the probe wire (green) from the 

probe end to the body of the brewer should stop the fill if 

the probe is bad but the liquid level board is good) 

 

Bad liquid level control board 

-Replace the LLC board if grounding the probe end of the 

(green) probe wire to the body of brewer does not remove 

the voltage at the fill terminal on the LLC board. 

 

Bad or stuck fill valve 

-Rebuild or replace the fill valve if no voltage is on the coil 

(it is not magnetic) and it still passes water to the tank. 

(Disconnect the outlet side to see if it leaks water to the 

tank) 

Coffee tastes too strong

 

Incorrect dosage 

-Measure and confirm the correct amount of coffee required 

 

Short brew levels 

-See “Short brew levels”, above. 

 

Temperature Problem (brewer 

only) 

Possible Cause 

Solution 

See also LUXUS problems 

 

 

Brew water is cold / not hot enough, 

ready light is OFF. 

(Before proceeding, make sure water tank 

refills when water is dispensed. The 

brewer will not heat unless the tank is full.) 

No power to brewer. 

-Make sure power switch is on. 

-Reset machine circuit breaker. 

-Check power connection. (plug or hard wire connection). 

-Check building circuit breaker. (Always reset breaker by 

switching off, then on.) 

 

Defective liquid level control board.  

(No power to thermostat). 

-With power on, and water tank full, check LLC board for 

120 volts on brown wire and neutral.  Replace LLC board if 

there is no voltage. 

 

Bad connections on solid state relay.  

(No power to heaters). 

-Check relay for burned or loose connections.  Replace 

with high temperature connectors if necessary. 

 

Defective solid state relay.  

(No power to heaters). 

-Check input and output voltages on relay. 120 volts on 

blue wire (input) but no voltage out to heaters indicates a 

bad relay. 

 

Bad heating element/s.  

 

-Check amperage draw on heater wires. 0 amps = bad 

heater. 

Brew water is cold / not hot enough, 

ready light is   ON. 

 

Bad Thermostat 

(the thermostat believes that it is at 

set temperature) 

-Replace the thermostat and or thermal probe. It’s not 

possible to trouble shoot the probe. 

 

Low brew temperature setting on 

thermostat 

-See “Low brew temperature” under “

Weak Coffee”

 

section. 

Slow to recover temperature 

 

Brewers with more than one heater 

can have just one fail 

-Check amperage draw on heater wires. 0 amps = bad 

heater. 

(Ready light takes along time to come 

back on after brewing.) 

Hot water tank limed up 

-Remove access cover to the hot water tank and inspect 

for lime. Remove the brewer for shop de-liming if build up 

is thick. 

Boiling 

Thermostat set too high for altitude 

(Denver etc.) 

-Reduce temperature setting to 3 degrees below boiling at 

your altitude 

 

Defective thermostat 

-Replace the thermostat and or thermal probe. It’s not 

possible to trouble shoot the probe. 

 

Содержание CBS-5000H Series

Страница 1: ...ingle1 Gal CBS 51H15 Right Dual 2 Gal CBS 52H20 Contact Information FETCO Food Equipment Technologies Company 600 Rose Road Lake Zurich IL 60047 1560 USA 2008 2019 Food Equipment Technologies Company...

Страница 2: ...lf batch brewing capability Fully automatic with electronic temperature control Iced tea brewing capability Two level tank drain system Total serviceability from the front Can be added at any time Spe...

Страница 3: ...ph 3 ground 6 1 25 8 9 9 22 0 120 208 1 ph 3 ground 6 1 29 6 9 9 22 0 C52026 2 X 4000 watt 120 220 1 ph 3 ground 6 8 31 3 11 5 22 0 120 240 1 ph 3 ground 8 1 34 1 13 2 22 0 120 208 3 ph 4 ground 6 9...

Страница 4: ...Go to fetco com for the latest versions of all information Page 4 P183 March 2019 Dimensions Utility Connections CBS 51H15 CBS 52H15 CBS 52H20...

Страница 5: ...ing Verify that the brewer will fit in the space intended for it and that the counter or table will support the total weight of the brewer and dispensers when filled 2 The brewer s legs are shipped in...

Страница 6: ...tubes 2 Turn on the incoming power 3 Turn on the brewer s main power switch 4 Within 6 seconds the hot water tank will begin filling until the probe at the top of the tank senses the water 5 The contr...

Страница 7: ...ion This was done to help draw attention to the basket so the operator will notice any residual hot water or coffee Place a paper filter in each basket to be used Pour into the paper filter the approp...

Страница 8: ...never the power switch is turned on voltage will not be supplied to the thermostat until the tank fills and water touches the water level probe During operation when water is dispensed and the water l...

Страница 9: ...cutter controls the rate of flow over the coffee The standard hole in the flow disc is 240 except for the CBS 51H10 which is 219 Other flow discs are available for special situations like high levels...

Страница 10: ...ISPENSE TUBE SHAFT DISPENSE TUBE To remove the dispense tube 1 Unscrew seal locknut and release the drive screw from dispense tube shaft 2 Turn the dispense tube slightly back and forth while pushing...

Страница 11: ...will flash indicating that the display is showing the set point not the actual temperature The dots below the numbers indicate the temp range 0 dots less than 100 F 1 dot between 100 and 200 F 2 dots...

Страница 12: ...is energized Bypass Adjustment The purpose of the bypass valve is to allow a portion of the brewing water to flow between the brew basket and the wire insert directly into the server without coming in...

Страница 13: ...NUT SEAL 7 16 DIA KEEPER 17 2 1031 00033 00 LOCKNUT 3 8 18 NPT THREAD 18 1 1031 00022 00 FITTING ELBOW 3 8 TUBE OD X 3 8 NPT 19 1 1023 00003 00 LOCKNUT MODIFIED THREAD 1 4 18 NPT 20 1 1083 00006 00 WA...

Страница 14: ...Go to fetco com for the latest versions of all information Page 14 P183 March 2019 Figure 2 CBS 51H15 Main Assembly Drawing No 1101 00268 00 CBS 51 H...

Страница 15: ...AMP READY INDICATOR GREEN 220VAC EXPORT ONLY 26 1 1045 00022 00 OVERLAY CONTROL PANEL CBS 51H 27 1 1058 00011 00 LAMP BREW INDICATOR CLEAR 110VAC 27 1 58004 LAMP BREW INDICATOR CLEAR 220VAC EXPORT ONL...

Страница 16: ...Go to fetco com for the latest versions of all information Page 16 P183 March 2019 Figure 3 CBS 52H15 CBS 52H20 Main Assembly Drawing No 1101 00262 00 CBS 52H...

Страница 17: ...SPRAY CUTTER 8 1 075 CENTER 29 2 1012 00004 00 LOCKNUT SPRAY CUTTER 30 2 25001 TUBESILICONE 1 2 x 1 4 ID x 2 7 8 LG 31 2 1112 00041 00 DISPENSE TUBE WELDMENT CBS 50 S 32 1 102010 BREW HANDLE START STO...

Страница 18: ...00024 00 FITTING COMP MALE CONN 3 8 TUBE X 3 8 17 1 1031 00020 00 LOCKNUT 1 8 STRAIGHT PIPE THREAD 18 1 1083 00014 00 WASHER 812 OD X 0 412 ID FLAT 19 1 1031 00032 00 FITTING BARB ELBOW 90 1 4 HOSE ID...

Страница 19: ...BREW BASKET HANDLE BLACK includes magnet 3 1 1082 00040 00 HANDLE SCREW 4 1 1009 00005 00 WIRE INSERT 16 X 6 5 1 1046 00025 00 WARNING LABEL NOT SHOWN F001 PAPER FILTERS 15 X 5 5 500 PER CASE NOT SHO...

Страница 20: ...evels are erratic Water pressure or flow rate is too low or fluctuates too much to support a full brew problem is worse in simultaneous brews Make sure brewer has a dedicated water line Ensure that th...

Страница 21: ...isconnect the outlet side to see if it leaks water to the tank Coffee tastes too strong Incorrect dosage Measure and confirm the correct amount of coffee required Short brew levels See Short brew leve...

Страница 22: ...End of section notes N...

Отзывы: