Go to fetco.com for the latest versions of all information Page 11
P183 March 2019
Adjustments
Thermostat Adjustment:
During normal operation, the digital readout displays the last two digits of the actual water temperature. When the
adjustment tool is turned, the readout begins flashing to indicate the set point, not the actual temperature. After the
tool is released, the readout stops flashing and displays the actual temperature again.
A red LED lights when the power to the thermostat is on. A yellow LED lights when the thermostat is calling for
heat.
To adjust, turn the adjustment tool. If no adjustment tool is present, a small flat-head screwdriver may be used. The
display will flash, indicating that the display is showing the set point, not the actual temperature.
The dots below the numbers indicate the temp range.
0 dots – less than 100° F
1 dot – between 100° and 200° F
2 dots – over 200° F
Examples:
7 5
= 75°F
8 7
= 187°F
0 3
=
203°F
Chart to correct for altitude boiling point difference
in tank water temperature
.
[ft]
[m]
Suggested
Setting[°F]
Boiling
point[°F]
Suggested
Setting[°C
]
Boiling
point [°C]
0
0
205
212.0
96
100.0
500
152
205
211.0
96
99.5
1000 305
200
210.1
93
98.9
2000 610
200
208.1
93
97.8
2500 762
200
207.2
93
97.3
3000 914
200
206.2
93
96.8
3500 1067
197
205.3
92
96.3
4000 1219
195
204.3
91
95.7
4500 1372
194
203.4
90
95.2
5000 1524
194
202.4
90
94.7
5500 1676
193
201.5
89
94.2
6000 1829
192
200.6
89
93.6
6500 1981
191
199.6
88
93.1
7000 2134
190
198.7
87
92.6
7500 2286
188
197.8
86
92.1
8000 2438
187
196.9
86
91.6
8500 2591
185
196.0
85
91.1