3. Installation
3-13
Festo P.BE-VTSA-44-EN en 1101f
In the operating mode for ducted pilot and venting air via
duct (12) (see 5.4.1), there must be no pressure at duct (12),
since otherwise the valves cannot switch.
Therefore, please note the following points if you wish to use
duct (12) for ducted pilot and venting air:
–
The valve terminal is not equipped with reversible
2x2/2- or 2x3/2-way valves.
–
The valve terminal is not equipped with valves from other
manufacturers.
–
The seals between the manifold sub-bases and the
valves must be mounted in the appropriate position
(see Chapter 5.4.1).
–
Valve terminals with a selector end plate must be operated
in positions 3 or 4 of the selector plate (see Tab. 3/2).
3.4.2
Pilot control of the solenoid coils (pilot air supply)
Note
•
The VTSA... valve terminal can either be supplied with
internal pilot air via the type VABF-S6-1-P5A4-.. soft-start
valve or with internal or external pilot air via the corres-
ponding right end plate.
•
The connection seal used for the soft-start valve de-
termines whether the internal pilot air is supplied via
the soft-start valve or the right end plate (see assembly
instructions for VABV-S6-1Q-...). If the supply of internal
pilot air via the soft-start valve is selected, there must be
no other pilot air supply feed (duct (14)) within the valve
terminal. Exhaust air cannot be expelled via the soft-
start valve. An exhaust plate is required for operation in
a pressure zone with separated ducts (1) and (3/5).
Содержание VTSA-44-ASI Series
Страница 2: ......
Страница 16: ...Contents and general instructions XIV Festo P BE VTSA 44 EN en 1101f ...
Страница 17: ...Summary of components 1 1 Festo P BE VTSA 44 EN en 1101f Chapter 1 Summary of components ...
Страница 63: ...Fitting 2 1 Festo P BE VTSA 44 EN en 1101f Chapter 2 Fitting ...
Страница 79: ...Installation 3 1 Festo P BE VTSA 44 EN en 1101f Chapter 3 Installation ...
Страница 87: ...3 Installation 3 9 Festo P BE VTSA 44 EN en 1101f 1 2 3 Fig 3 1 Mounting the tubing connections ...
Страница 89: ...3 Installation 3 11 Festo P BE VTSA 44 EN en 1101f 1 2 4 3 Fig 3 2 Removing the tubing ...
Страница 125: ...Commissioning 4 1 Festo P BE VTSA 44 EN en 1101f Chapter 4 Commissioning ...
Страница 142: ...4 Commissioning 4 18 Festo P BE VTSA 44 EN en 1101f ...
Страница 143: ...Maintenance and conversion 5 1 Festo P BE VTSA 44 EN en 1101f Chapter 5 Maintenance and conversion ...
Страница 167: ...Technical appendix A 1 Festo P BE VTSA 44 EN en 1101f Appendix A Technical appendix ...
Страница 192: ...A Technical appendix A 26 Festo P BE VTSA 44 EN en 1101f A 2 Accessories For accessories see www festo com catalogue ...
Страница 193: ...Supplementary component summary B 1 Festo P BE VTSA 44 EN en 1101f Appendix B Supplementary component summary ...
Страница 210: ...B Supplementary component summary B 18 Festo P BE VTSA 44 EN en 1101f ...
Страница 211: ...Index C 1 Festo P BE VTSA 44 EN en 1101f Appendix C Index ...
Страница 212: ...C Index C 2 Festo P BE VTSA 44 EN en 1101f Contents C Stichwortverzeichnis C 1 ...
Страница 220: ...C Index C 10 Festo P BE VTSA 44 EN en 1101f ...