Fig. 14 Measured value indicator (SHOW mode)
Legend
Meaning
Edit button
A pushbutton, B pushbutton or A and B pushbutton
Tab. 17 Legend for Measured Value Indicator (SHOW Mode)
9
Operation and Use
9.1
Notes on Operation
Type SOPA-C..
•
To prevent the contamination of the sensor modules and the measuring
nozzles, switch on the instrument air.
•
Activate the exhaust air to clean contaminated measuring nozzles.
The switching status of the valves, which are integrated in the control module and
used for activating the measuring and exhaust air, is indicated by the status LED
[Sense] and [Clean].
Type SOPA-C..-H
•
The electric manual override function for the measuring and exhaust air on
the control module can be deactivated by switching off the supply voltage for
the manual override.
Ä
The LED which indicates the ready status of the manual override is then
switched off.
9.2
Restoring Factory Settings (Restore)
By resetting to the factory settings, the current settings are lost. Note down cur-
rent settings before resetting.
1. Switch off operating voltage.
2. Press and hold the A pushbutton, B pushbutton and Edit button.
3. Switch on the operating voltage.
Ä
–
[CLER] is displayed.
–
The factory settings are restored
è
Fig.13. RUN mode is active.
9.3
Using the Differential Pressure Regulator
In order to enable faster response times with low measuring distances or com-
pletely sealed measuring nozzles, a differential pressure regulator
(LRLL-1/8-QS-6) can be used instead of the vent screw. The valve function
enables the pressure to be exhausted significantly quicker than via the vent
screw.
Connecting and Checking the Differential Pressure Regulator
1. Remove the vent screw (SW 14).
2. Mount the differential pressure regulator (LRLL-1/8-QS-6) to the connection
for the vent screw (
è
Fig.3).
3. Press the CLEAN pushbutton (CLEAN = OFF) and then the SENSE pushbutton
(SENSE = ON) on the control module.
4. Make sure that no object is inserted in the area of the measuring nozzles
è
5. Turn the adjusting screw on the differential pressure regulator clockwise
(towards LOW) until no air flows from the differential pressure regulator.
6. Turn the adjusting screw on the differential pressure regulator counter-clock-
wise (towards HIGH) until air starts to flow from the differential pressure reg-
ulator.
Checking the Settings of the Differential Pressure Regulator
1. Seal the measuring nozzle (for example, clamp the workpiece).
2. Press the CLEAN key (CLEAN = OFF) on the control module.
Ä
Sensor module is supplied with operating pressure. [SUP.P] is displayed.
3. Press and hold the SENSE button (SENSE = ON) on the control module until
[SUP.P] is no longer displayed.
4. If the delay ([SUP.P] in the display) is too great, reduce the time by turning the
control valve (towards HIGH).
10
Maintenance and Care
1. Switch off the energy sources (operating voltage, compressed air).
2. Clean sensor with non-abrasive cleaning agents.
11
Malfunctions
11.1
Fault Clearance
Fault description
Cause
Remedy
Supply voltage not applied or
permitted operating voltage not
present
Switch on the supply voltage;
observe the voltage range.
Electrical connections swapped
(incorrect polarity)
Connect the sensor module in
accordance with the plug pat-
tern.
No indication on display
Sensor module defective
Replace sensor module.
Incomplete display
Display faulty
Replace sensor module.
Incorrect pressure indicator for
supply pressure (InC)
Sensor module contaminated
Replace the sensor module and
operate the sensor only with
filtered compressed air
è
Value InC (supply pressure)
outside the measuring range
(
>
2 bar)
Maintain pressure range
è
Measured value indicator
(7-segment) flashes
Overpressure above permitted
overload pressure (device dam-
aged)
Replace sensor module.
Short circuit or overload at the
output
Rectify short circuit/overload.
Outputs do not switch in
accordance with the settings
Sensor module defective
Replace sensor module.
Settings cannot be edited
(Lock)
Access protection active
Enter security code or reset
device to factory setting
1)
.
Long response times after the
CLEAN function with virtually
closed or completely closed
measuring nozzles
Pressure reduction for the
measuring nozzle too slow
Replace the vent screw with a
differential pressure regulator
è
No 'ready for operation' signal
when using a differential pres-
sure regulator
No pressure reduction for the
measuring nozzle
Adjust the differential pressure
regulator
è
1) If the security code can no longer be found
Tab. 18
11.2
Error Messages
Indication on display
Error
Remedy
[Er01]
Sensor module defective
Replace sensor module.
[Er13]
1)
Supply pressure (InC) outside
the measuring range (
<
0 ,
<
0 MPa); no signal evaluation
possible
Comply with the measuring
range
è
[Er14]
1)
Supply pressure (InC) outside
the measuring range (
>
2 bar,
>
0.2 MPa); no signal evalu-
ation possible
Comply with the measuring
range
è
[Er17]
2)
Undervoltage in supply voltage.
Observe the voltage range
è
[Er21]
Short circuit/overload at
switching output OutA (only for
SOPA -...- PNLK)
Rectify short circuit/overload.
Supply pressure switched off
Apply supply pressure
è
Wait until the exhaust air is
completely out of the system.
[SUP.P]
Exhaust air in the system
Use/set differential pressure
regulator.
[Er.Co]
IO-Link communication error
Check line OutA.
Check settings of the device
sensor.
[Er.Id]
IO-Link Device ID error, devices
do not have the same design
When replicating, use sensors
with the same pressure range /
type (same device ID).
1) Display only in SHOW mode
2) Display flashes. The lowest current error number is shown. The outputs are reset automatically.
Tab. 19 Possible Error Messages of the Sensor Module
12
Disassembly
1. Switch off the energy sources (operating voltage, compressed air).
2. Disconnect the connections for the control module and the sensor modules.
3. Remove device.