SOPA -...- PNLK

Pin

Wire colour

1)

Allocation

Plug

1

Brown (BN)

Operating v24 V DC

2

White (WH)

Analogue output VB or A

3

Blue (BU)

Operating voltage 0 V

4

Black (BK)

Switching output for OutA or OutC (C/Q
line with IO-Link)

5

Grey (GY)

n.c = free (not connected)

M12, 5-pin

1) When using the connecting cable as per Accessories.

Tab. 14 Pin Allocation for Sensor Module

SOPA -...-...-...- PNLK-VB -...

SOPA -...-...-...- PNLK-A -...

Tab. 15 Circuit Diagrams for Sensor Module

8

Commissioning

8.1

Commissioning the Sensor

Switch on the operating voltage.

Ä

RUN mode is active.

To activate the RUN mode at any time, press and hold the Edit button for 3
seconds.

8.2

Setting Switching Point A

Switching output OutA is preset for distance monitoring. The switching point for
OutA must be set or taught manually.

Option 1: Manually Setting the Switching Point for OutA

1. Press the Edit button.

Ä

EDIT mode is active. [OutA] flashes. With active security blocking, [Lock]
flashes.

2. Enter the set security code using the A or B pushbutton.
3. Press the Edit button to confirm the selection.

Ä

[SP] flashes.

4. Set switching point with the A or B pushbutton.
5. Press and hold the EDIT button for 3 seconds.

Ä

RUN mode is active.

Option 2: Teaching-in the Switching Point for OutA

1. Establish the desired switching distance between the object and the measur-

ing nozzle.

2. Press A pushbutton and keep it pressed.
3. Additionally, press the Edit button.

Ä

[OutA] and [TeachIn] flash. The value is adopted as the switching
point.

[Lock] flashes: safety lock active. The value is buffered.

4. Enter the set security code using the A or B pushbutton.
5. Press the Edit button.

Ä

[OutA] and [TeachIn] flash. The cached value is taken over as the
switching point.

RUN mode is active.

8.3

Menu Structure (EDIT Mode)

Some menu options or setting values are not applicable, depending on the
product variant and the selected switching function.

Fig. 13 Menu Structure (EDIT Mode)

Legend

Meaning

Edit button

A or B pushbutton

Bold

Factory setting

1)

Menu column only for PNLK-VB/A

2)

Menu item only with PNLK-VB

3)

Menu item only for PNLK-VB/A

4)

Menu column and menu item only for 2P/2N

Tab. 16 Legend for Menu Structure EDIT Mode

8.4

Displaying Parameters (INFO/SHOW Mode)

Requirement: the sensor is ready for operation (RUN mode).
1. Press A pushbutton, B pushbutton or A and B pushbutton.

Ä

Display shows the respective input value or an error number.

2. To display each of the following parameters, press the A pushbutton, B push-

button or A and B pushbutton 

è

 Fig.13.

3. At the end of the SHOW mode, the respective minimum and maximum values

are displayed. To reset the display of the minimum and maximum values,
press the Edit button.

Ä

RUN mode is active.

Содержание SOPA Series

Страница 1: ...be used with a Class 2 power source or Class 2 trans former in accordance with UL1310 or UL1585 As an alternative a LV C Limited Voltage Current power source with one of the following properties can b...

Страница 2: ...ft and right and C illuminate min or max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments illuminate and Option flashes EDIT mode active Special menu ope...

Страница 3: ...NC normally closed In Supply pressure Switching function 2 switching points SPmin SPmax IO Link SP1 SPmin SP2 SPmax No TEACH mode Tab 7 Window Comparator Hysteresis Hysteresis serves to suppress switc...

Страница 4: ...supply use only PELV circuits in accordance with IEC 60204 1 EN 60204 1 Protective Extra Low Voltage PELV Observe the general requirements of IEC 60204 1 EN60204 1 for PELV cir cuits Only use voltage...

Страница 5: ...the desired switching distance between the object and the measur ing nozzle 2 Press A pushbutton and keep it pressed 3 Additionally press the Edit button OutA and TeachIn flash The value is adopted a...

Страница 6: ...s 11 Malfunctions 11 1 Fault Clearance Fault description Cause Remedy Supply voltage not applied or permitted operating voltage not present Switch on the supply voltage observe the voltage range Elect...

Страница 7: ...able Switching function OutA Threshold value comparator with variable hysteresis OutB Threshold value comparator with variable hysteresis OutC Window Comparator Switching element function N C contact...

Страница 8: ...35 mm to DIN EN 60068 part 2 6 Tab 31 Immissions Emissions IO Link Protocol version Device V1 1 Device V1 1 Smart sensor profile Function classes Switching signal channel SSC Process data variable PDV...

Отзывы: