6.2.3
Wall Mounting
1 Adapter plate
Fig. 10 Wall Mounting
1. Mount adapter plates (e.g. 2 x M3).
–
Hole patterns and dimensions
è
2. Hang the sensor in the adapter plates and press until the fastening slide clips
in.
6.3
Attaching the Sensor Module without a Control Module
The supply pressure can be fed from the left and/or right-hand side.
1 Connection for supply pressure
Fig. 11 Attach the sensor modules
1. Mount the fitting (thread M7) to the supply pressure port.
–
Thread length: max. 5.5 mm
2. Seal the exposed connection with a blanking plug.
–
SW: 3 mm
6.4
Accessories
Identifier
Type
Straight socket
NEBU-M12G5-K-...
Connecting cable
Angled socket
NEBU-M12W5-K-...
Differential pressure regulator
LRLL-1/8-QS-6
Adapter plate for wall mounting
1)
SXE3-...-W...
Blanking plug
B-M7
Push-in fitting
QSM-M7-6-I
1) Included in the scope of delivery for SOPA -...- W -...
Tab. 8 Accessories SOPA
7
Installation
7.1
Pneumatic Installation
1 Control module
2 Sensor module
Fig. 12 Pneumatic Installation
1. Insert tubing into push-in fitting.
–
Outside diameter: 6 mm
2. Connect the supply port for the measuring nozzle to the corresponding meas-
uring nozzle
è
3. For operation with a control module: connect supply port for operating medi-
um to the compressed air source.
For operation without a control module: connect the supply port for the sup-
ply pressure to the precision pressure regulator.
4. Ensure adequate exhaust at the vent screw connection (via vent screw or dif-
ferential pressure regulator (LRLL-1/8-QS-6)
è
Tubing at Standstill
•
To avoid contamination of the measuring nozzles, remove the vent screw and
use this connection to supply purge air.
7.2
Electrical Installation
WARNING!
Risk of injury due to electric shock.
•
For the electrical power supply, use only PELV circuits in accordance with IEC
60204-1/EN 60204-1 (Protective Extra-Low Voltage, PELV).
•
Observe the general requirements of IEC 60204-1/EN60204-1 for PELV cir-
cuits.
•
Only use voltage sources that ensure a reliable electric separation from the
mains network in accordance with IEC 60204-1/EN 60204-1.
1. Use signal lines that are shorter than 30 m.
2. Configure binary outputs according to the wiring (only with PNLK sensor mod-
ules).
–
Tightening torque for the union nut at the plug connector: max. 0.3 Nm
7.2.1
PIN Allocation and Control Module Circuit Diagrams
Pin
Wire colour
1)
Allocation
Plug
1
Brown (BN)
Operating v24 V DC
2
White (WH)
Switch on signal input exhaust air (Clean)
3
Blue (BU)
Operating voltage 0 V
4
Black (BK)
Switch on signal input instrument air
(Sense)
5
Grey (GY)
n.c = free (not connected)
M12, 5-pin
1) When using the connecting cable as per Accessories.
Tab. 9 Pin Allocation for Control Module
SOPA-C..-H-...-...-2P-...
1)
SOPA-C..-H-...-...-2N-...
BN
BK
BU
+24 V
0 V
WH
PNP
1
4
3
2
5
Sense
Clean
BN
BK
BU
+24 V
0 V
WH
NPN
1
4
3
2
5
Sense
Clean
1) in combination with PNLK sensor modules
Tab. 10 Circuit Diagrams for Control Module with Manual Override
SOPA-C..-...-...-2P-...
1)
SOPA-C..-...-...-2N-...
BK
BU
+24 V
0 V
WH
PNP
1
4
3
2
5
Sense
Clean
BN
BK
+24 V
0 V
WH
NPN
1
4
3
2
5
Sense
Clean
1) in combination with PNLK sensor modules
Tab. 11 Circuit Diagrams for Control Module without Manual Override
7.2.2
PIN Allocation and Sensor Module Circuit Diagrams
SOPA-...-2P/-2N
Pin
Wire colour
1)
Allocation
Plug
1
Brown (BN)
Operating v24 V DC
2
White (WH)
Switching output for OutB or OutC (factory
setting)
3
Blue (BU)
Operating voltage 0 V
4
Black (BK)
Switching output for OutA
5
Grey (GY)
n.c = free (not connected)
M12, 5-pin
1) When using the connecting cable as per Accessories.
Tab. 12 Pin Allocation for Sensor Module
SOPA-...-...-...-2P-M12-...
SOPA-...-...-...-2N-M12-...
BN
BK
BU
R
L
+24 V
0 V
WH
P
R
L
PNP
1
4
3
2
5
BN
BK
BU
+24 V
0 V
WH
P
NPN
1
4
3
2
5
R
L
R
L
Tab. 13 Circuit Diagrams for Sensor Module