Festo SOPA Series Скачать руководство пользователя страница 8

SOPA-...

-C

-M

Sealing ring

HNBR, NBR

HNBR, FPM, NBR

Adapter plate SOPA-...-W-...

Chromated steel

Tab. 29 Materials

SOPA-...-M-...

Display range InA/InB
(distance)

0 … 500 (dimensionless)

[MPa]

0 … 0.2

Display range InC
(supply pressure)

1)

[psi]

0 … 29

[bar]

0 … 2

Setting range threshold value
OutA/OutB (distance)

20 … 300 (dimensionless)

[MPa]

0.05 … 0.19

[psi]

7.3 … 28

Setting range threshold value
OutC (supply pressure)

1)

[bar]

0.5 … 1.9

Setting range hysteresis
OutA/OutB (distance)

3 … 20 (dimensionless)

[MPa]

0.005

Hysteresis OutC
(supply pressure)

1)

[psi]

0.7

[bar]

0.05

1) Value for InC and OutC are only shown in bar in the display.

Tab. 30 Display/Operation

SOPA-...

-C

-M

Storage temperature

[°C]

–20 … +80

Degree of protection

IP65 (in accordance with EN 60529)

Internal air consumption

[Nl/min]

Typ. 4.5

Instrument air consumption
(sense)

[Nl/min]

Typ. 15 (per measuring
module)

Blow out air consumption
(clean)

[Nl/min]

Typ. 35 (per measuring
module)

Protection class 

III (in accordance with DIN VDE 0106-1)

Shock resistance

30 g acceleration with 11 ms duration (half-sine) (to
DIN EN 60068 part 2-27)

Vibration resistance

5 g acceleration at 10 … 150 Hz / 35 mm
(to DIN EN 60068 part 2-6)

Tab. 31 Immissions/Emissions

IO-Link

Protocol version

Device V1.1

Device V1.1

Smart sensor profile

Function classes

Switching signal channel (SSC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel 

Communication mode

COM2 (38.4 kbaud)

SIO mode support

Yes

Port class

O

Process data width IN

2 bytes

Process data content IN

2 bit SSC (distance monitoring)
1 bit SSC (supply pressure monitoring)
10 bit PDV (distance)

Service data IN

14 bit (supply pressure)

Cycle time

³

 3 ms

Device ID

SOPA -...- PNLK-VB

0xC0 (192)

SOPA -...- PNLK-A

0xC1 (193)

IODD, IO-Link® device description

è

 www.festo.com/sp

Tab. 32 IO-Link

14.2

Diagrams

Response Times for Different Tube Lengths

Fig. 17 Typical response time t as a function of distance x after switching on the
instrument air (measuring nozzle: 2 mm)

Fig. 18 Typical response time t as a function of distance x after switching off the
exhaust air (measuring nozzle: 2 mm)

Displays for Different Tube Lengths

Fig. 19 Influence of the tubing length on the dimensionless display value (measur-
ing nozzle 2 mm)

Repetition Accuracy of the Switching Point

Fig. 20 Repetition accuracy of the switching point [±μm] as a function of the
switching point distance x (measuring nozzle: 2 mm)

14.3

Hole Patterns

Fig. 21 Hole Patterns

Содержание SOPA Series

Страница 1: ...be used with a Class 2 power source or Class 2 trans former in accordance with UL1310 or UL1585 As an alternative a LV C Limited Voltage Current power source with one of the following properties can b...

Страница 2: ...ft and right and C illuminate min or max flash SHOW mode active 7 segment display shows the minimum or maximum value InC Marked segments illuminate and Option flashes EDIT mode active Special menu ope...

Страница 3: ...NC normally closed In Supply pressure Switching function 2 switching points SPmin SPmax IO Link SP1 SPmin SP2 SPmax No TEACH mode Tab 7 Window Comparator Hysteresis Hysteresis serves to suppress switc...

Страница 4: ...supply use only PELV circuits in accordance with IEC 60204 1 EN 60204 1 Protective Extra Low Voltage PELV Observe the general requirements of IEC 60204 1 EN60204 1 for PELV cir cuits Only use voltage...

Страница 5: ...the desired switching distance between the object and the measur ing nozzle 2 Press A pushbutton and keep it pressed 3 Additionally press the Edit button OutA and TeachIn flash The value is adopted a...

Страница 6: ...s 11 Malfunctions 11 1 Fault Clearance Fault description Cause Remedy Supply voltage not applied or permitted operating voltage not present Switch on the supply voltage observe the voltage range Elect...

Страница 7: ...able Switching function OutA Threshold value comparator with variable hysteresis OutB Threshold value comparator with variable hysteresis OutC Window Comparator Switching element function N C contact...

Страница 8: ...35 mm to DIN EN 60068 part 2 6 Tab 31 Immissions Emissions IO Link Protocol version Device V1 1 Device V1 1 Smart sensor profile Function classes Switching signal channel SSC Process data variable PDV...