SOPA-...
-C
-M
Sealing ring
HNBR, NBR
HNBR, FPM, NBR
Adapter plate SOPA-...-W-...
Chromated steel
–
Tab. 29 Materials
SOPA-...-M-...
Display range InA/InB
(distance)
0 … 500 (dimensionless)
[MPa]
0 … 0.2
Display range InC
(supply pressure)
1)
[psi]
0 … 29
[bar]
0 … 2
Setting range threshold value
OutA/OutB (distance)
20 … 300 (dimensionless)
[MPa]
0.05 … 0.19
[psi]
7.3 … 28
Setting range threshold value
OutC (supply pressure)
1)
[bar]
0.5 … 1.9
Setting range hysteresis
OutA/OutB (distance)
3 … 20 (dimensionless)
[MPa]
0.005
Hysteresis OutC
(supply pressure)
1)
[psi]
0.7
[bar]
0.05
1) Value for InC and OutC are only shown in bar in the display.
Tab. 30 Display/Operation
SOPA-...
-C
-M
Storage temperature
[°C]
–20 … +80
Degree of protection
IP65 (in accordance with EN 60529)
Internal air consumption
[Nl/min]
Typ. 4.5
–
Instrument air consumption
(sense)
[Nl/min]
–
Typ. 15 (per measuring
module)
Blow out air consumption
(clean)
[Nl/min]
–
Typ. 35 (per measuring
module)
Protection class
III (in accordance with DIN VDE 0106-1)
Shock resistance
30 g acceleration with 11 ms duration (half-sine) (to
DIN EN 60068 part 2-27)
Vibration resistance
5 g acceleration at 10 … 150 Hz / 35 mm
(to DIN EN 60068 part 2-6)
Tab. 31 Immissions/Emissions
IO-Link
Protocol version
Device V1.1
Device V1.1
Smart sensor profile
Function classes
Switching signal channel (SSC)
Process data variable (PDV)
Identification
Diagnostics
Teach channel
Communication mode
COM2 (38.4 kbaud)
SIO mode support
Yes
Port class
O
Process data width IN
2 bytes
Process data content IN
2 bit SSC (distance monitoring)
1 bit SSC (supply pressure monitoring)
10 bit PDV (distance)
Service data IN
14 bit (supply pressure)
Cycle time
³
3 ms
Device ID
–
SOPA -...- PNLK-VB
0xC0 (192)
–
SOPA -...- PNLK-A
0xC1 (193)
IODD, IO-Link® device description
è
Tab. 32 IO-Link
14.2
Diagrams
Response Times for Different Tube Lengths
Fig. 17 Typical response time t as a function of distance x after switching on the
instrument air (measuring nozzle: 2 mm)
Fig. 18 Typical response time t as a function of distance x after switching off the
exhaust air (measuring nozzle: 2 mm)
Displays for Different Tube Lengths
Fig. 19 Influence of the tubing length on the dimensionless display value (measur-
ing nozzle 2 mm)
Repetition Accuracy of the Switching Point
Fig. 20 Repetition accuracy of the switching point [±μm] as a function of the
switching point distance x (measuring nozzle: 2 mm)
14.3
Hole Patterns
Fig. 21 Hole Patterns