In Show mode, depending on whether the A- or B- button is pressed, the current settings for the switch-
ing outputs Out A or Out B will be shown.
The SFAM must be in RUN mode.
•
When air consumption is active, INFO- mode enables rapid switching of the input variables flow and
air consumption in the display by pressing the A- or B-button.
Note
If there are faults, pressing the A button / B button first displays corresponding fault
numbers.
•
Repeated pressing of the A button / B button displays the settings of the respective switching out-
put one after another.
•
At the end of the SHOW-mode the Min-value [F.Lo] and the Max-value [F.Hi] will be shown. If no
further keys are pressed the Min / Max values remain permanently (no timeout). In the process the
Min- or Max- displays are signalled
Tab. 8: by the blinking of Segment 1 or Segment 10 in the bar
graph.
•
The Min / Max values can be reset by pressing the Edit knob.
•
When all settings have been displayed, the SFAM goes back into RUN mode when the A button /
B button are pressed again and displays the current measurement value for the corresponding
output.