SFAM
Festo – SFAM – 1103a English
51
Icon
Meaning
Security code inactive (Lock)
Press button (here A button)
Press A button or B button. Then the SFAM switches to the setting shown by the
arrows.
Press A button and B button simultaneously
Press button (here button A) and EDIT button simultaneously
Press button A or button B and set the desired value
brief display (here [ANA.F] means that a value can be displayed.
Display for a value or switching point. Value can be set.
Press the Edit button
Branched in the menu
in SHOW mode shows the setting last chosen in EDIT mode
Tab. 9: Symbols for representing the menu structure
5.3
RUN mode
In the base state, the product is in the RUN mode. The current measurement value is displayed. The
base state can be reached from other modes by:
–
pressing Edit button for 3 seconds or
–
passage of a monitoring time, timeout
In the RUN mode
–
the measurement values for flow (in l/min or scfm)
–
the measurement values for air consumption (in m³, scf or l) and
–
the signal states of the switch outputs Out A, Out B (set, not set) are displayed.
1. Switch on the operating voltage.
The SFAM is in RUN mode.
2. Check the settings of the SFAM
chapter 5.4 SHOW mode.
Note
A flashing value means that the value was measured outside the permissible measuring
range.