SDE1−...
Festo SDE1−... 0511e English
57
12
Technical specifications
Type SDE1−
D10−...
D6−...
D2−...
B2−...
V1−...
Pressure measuring
range (p, p1, p2, p1−p2)
[bar]
0...10
0...6
0...2
−1...+1
0...−1
Overload pressure
[bar]
max. 20
max. 16
max. 6
max. 5
max. 5
Mounting position
Any; preferably vertical (risk of water condensing
and collecting in the unit)
Operating medium
Compressed air, filtered to 40 m,
lubricated or unlubricated
Vacuum
Setting range
Switching pressure/
vacuum:
Hysteresis:
[bar]
0.20...
9.98
0.00...
9.00
0.12...
5.99
0.00...
5.40
0.040...
1.996
0.000...
1.800
−0.999...
0.996
0.000...
1.800
−0.020...
−0.998
0.000...
0.900
Accuracy
at T = +20...25 °C
at T = 0...50 °C
[% FS]
Switching pressures: ±2; analog output: ±3
Switching pressures: ±3; analog output: ±4
Reproducibility
[% FS]
max. ±0.3 (short−time)
Ambient temperature
Media temperature
Storage temperature
[°C]
[°C]
[°C]
0...+50
0...+50
20...+80
Operating voltage range
[V DC]
15...30 V DC (permitted residual ripple max. 10 %)
Idle current
[mA]
Type SDE1−...−C:
max. 35 (approx. 30 typ.)
Type SDE1−...−L:
max. 45 (approx. 40 typ.)
Ready−state delay
[ms]
max. 450
(with suppression of spurious switch−on pulse)
Minimum operating
quality under influence
of noise
[% FS]
max. drift on analog output
<
5
Max. permitted signal
line length
[m]
30
Fig.20
Содержание SDE1 Series
Страница 30: ...SDE1 Festo SDE1 0511e Deutsch 30 Bild 23 EDIT Modus ...
Страница 31: ...SDE1 Festo SDE1 0511e Deutsch 31 1 1 1 Nur bei Typ SDE1 L UP Taste A oder DOWN Taste B erneut drücken ...
Страница 32: ...SDE1 Festo SDE1 0511e Deutsch 32 Bild 24 TEACH Modus ...
Страница 60: ...SDE1 Festo SDE1 0511e English 60 Fig 23 EDIT mode ...
Страница 61: ...SDE1 Festo SDE1 0511e English 61 1 1 1 Only with type SDE1 L press UP button A or DOWN button B again ...
Страница 62: ...SDE1 Festo SDE1 0511e English 62 Fig 24 TEACH mode ...
Страница 63: ...SDE1 Festo SDE1 0511e 63 de Lochbilder Adapterplatte en Hole pattern on adapter plate ...