7
Operation
Warning
Excessive internal heat will damage the SDE1−...
S
Avoid high cycle frequencies with large pressure amplitudes.
Otherwise the permitted maximum temperatures of the materials used will
be exceeded.
Reset the SDE1−... to the factory setting
(also if the security code cannot be found)
Please note
The current settings will be lost after a reset to the factory setting.
S
If necessary, make a note of these settings before a reset.
In order to reset the SDE1−... to the factory setting:
1. Switch off the operating voltage.
2. Press all three setting controls simultaneously (UP/DOWN button and EDIT
button) and switch the operating voltage on again.
8
Care and maintenance
Cleaning:
S
Switch off the following sources of energy before cleaning the exterior of the
unit:
operating voltage
compressed air/vacuum.
S
If necessary, clean the exterior of the SDE1−...
Soap suds (max. +60 °C), petroleum ether and all non−abrasive cleaning agents
may be used.
Содержание SDE1 Series
Страница 30: ...SDE1 Festo SDE1 0511e Deutsch 30 Bild 23 EDIT Modus ...
Страница 31: ...SDE1 Festo SDE1 0511e Deutsch 31 1 1 1 Nur bei Typ SDE1 L UP Taste A oder DOWN Taste B erneut drücken ...
Страница 32: ...SDE1 Festo SDE1 0511e Deutsch 32 Bild 24 TEACH Modus ...
Страница 60: ...SDE1 Festo SDE1 0511e English 60 Fig 23 EDIT mode ...
Страница 61: ...SDE1 Festo SDE1 0511e English 61 1 1 1 Only with type SDE1 L press UP button A or DOWN button B again ...
Страница 62: ...SDE1 Festo SDE1 0511e English 62 Fig 24 TEACH mode ...
Страница 63: ...SDE1 Festo SDE1 0511e 63 de Lochbilder Adapterplatte en Hole pattern on adapter plate ...