![Festo s CMMD-AS-C8-3A Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/festo/s-cmmd-as-c8-3a/s-cmmd-as-c8-3a_mounting-and-installation_2283257065.webp)
B
Diagnostic messages
Festo – GDCP-CMMD-AS-HW-EN – 1404NH – English
65
Error group 35
Fast stop
no.
Code
Message
Reaction
35-1
6199h
Time out with fast stop
PS off
Cause
The parameterised time for fast stop was exceeded.
Action
•
Check parameterisation.
Error group 40
Software limit
sorNo.
Code
Message
Reaction
40-0
8612h
Negative software limit switch reached
configurable
Cause
The position setpoint value has reached or exceeded the negative
software limit switch.
Action
•
Check the target data.
•
Check positioning area.
40-1
8612h
Positive software limit switch reached
configurable
Cause
The position setpoint value has reached or exceeded the positive
software limit switch.
Action
•
Check the target data.
•
Check positioning area.
40-2
8612h
Target position lies behind the negative software limit switch
configurable
Cause
Start of a positioning task was suppressed because the target lies
behind the negative software limit switch.
Action
•
Check the target data.
•
Check positioning area.
40-3
8612h
Target position lies behind the positive software limit switch
configurable
Cause
The start of a positioning task was suppressed because the target
lies behind the positive software limit switch.
Action
•
Check the target data.
•
Check positioning area.
Error group 41
Path program
no.
Code
Message
Reaction
41-8
6193h
Path program error, unknown command
configurable
Cause
Unknown command found during record continuation.
Action
•
Check parameterisation.
41-9
6192h
Error in path program jump destination
configurable
Cause
Jump to a positioning record outside the permitted range.
Action
•
Check parameterisation.