![Festo s CMMD-AS-C8-3A Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/festo/s-cmmd-as-c8-3a/s-cmmd-as-c8-3a_mounting-and-installation_2283257062.webp)
B
Diagnostic messages
62
Festo – GDCP-CMMD-AS-HW-EN – 1404NH – English
Error group 17
Following error monitoring
no.
Code
Message
Reaction
17-0
8611h
Following error monitoring
configurable
Cause
Comparison threshold for the limit value of the following error
exceeded.
Action
•
Enlarge error window.
•
Parameterise acceleration to be less.
•
Motor overloaded (current limiter from the I²t monitoring active?).
Error group 18
Output stage temperature monitoring
no.
Code
Message
Reaction
18-1
4280h
Output stage temperature 5 °C below maximum
configurable
Cause
The output stage temperature is greater than 90 °C.
Action
•
Check installation conditions, cooling through the housing
surface, integrated heat sink and back wall.
Error group 19
I²t monitoring
no.
Code
Message
Reaction
19-0
2380h
I²t at 80 %
configurable
Cause
Of the maximum I²t workload of the controller or motor, 80 % has
been achieved.
Action
•
Check whether motor/mechanics are blocked or sluggish.
Error group 21
Current measurement
no.
Code
Message
Reaction
21-0
5210h
Error, offset current measurement
PS off
Cause
The controller performs offset compensation of the current measu-
rement.
Tolerances that are too large result in an error.
Measure
If the error occurs repeatedly, the hardware is defective.
•
Send motor controller to the manufacturer.
Error group 22
PROFIBUS
no.
Code
Message
Reaction
22-0
7500h
Error in PROFIBUS initialization
PS off
Cause
Fieldbus interface defective.
Action
•
Please contact Technical Support.