- Exhaust port

2

3

3

4

4

5

5.5

6

6

7

9

11

Tab. 11 Minimum inside diameter of the connection tubes for connections with G-
female thread

Notes on the pneumatic connection

Maximum permissible tube length  2 m

OVEM-...-GN/-GO: minimum inside diameter of the connection tubes

è

 Tab. 11 Minimum inside diameter of the connection tubes for connections

with G-female thread.

Do not seal exhaust port.

OVEM-...-07/-10/-14/-20/-30: If necessary, lengthen silencers with a silencer
extension 

è

 www.festo.com/catalogue.

Recommendation: Use type PUN tubes 

è

 www.festo.com/catalogue.

7.2

Electrical installation

WARNING!

Risk of injury due to electric shock.

For the electrical power supply, use only PELV circuits in accordance with IEC
60204-1/EN 60204-1 (Protective Extra-Low Voltage, PELV).

Observe the general requirements of IEC 60204-1/EN60204-1 for PELV cir-
cuits.

Only use voltage sources that ensure a reliable electric separation from the
mains network in accordance with IEC 60204-1/EN 60204-1.

Connect the vacuum generator to the electrical connection.

5-pin plug, M12x1

Maximum tightening torque of M12 plug: 0.5 Nm

Maximum permissible cable length: 20 m

Plug

Pin

Wire
colour

1)

Function

1

brown (BN)

+24 V

2

white (WH)

Vacuum switching input

3

blue (BU)

0 V

4

black (BK)

Switching output (Out)

2)

5

grey (GY)

Switching input ejector pulse/power ejector pulse

1) When using the connecting cable as per Accessories 
2) Pin 4 not assigned for types without vacuum sensor

Tab. 12 Pin allocation OVEM-...-1PD

Circuit Diagrams

OVEM-...-1P

OVEM-...-1N

OVEM without vacuum sensor

Tab. 13 Circuit diagrams for vacuum generator

8

Commissioning

Commissioning by qualified personnel.

8.1

Quick commissioning

Factory settings:

Switching characteristics of the electrical output: threshold value comparator 

Switching function of the electrical output: N/O contact (normally open) 

Switching point (SP): -0.4 bar. Alternatively, teach-in switching point

è

 9.1 Teach-in switching point.

Fixed hysteresis (HYS): 20 mbar

1. Mount the vacuum generator 

è

 6 Assembly.

2. Connect the pneumatics for the vacuum generator

è

 7.1 Pneumatic installation.

3. Connect the electrics for the vacuum generator 

è

 7.2 Electrical installation.

The factory settings cannot be restored.

8.2

Commissioning the vacuum generator

At initial commissioning, the vacuum generator is placed in operation with the
factory settings .

Requirement

Vacuum generator is fully mounted and connected 

è

 6 Assembly.

Checking operating conditions

Check operating conditions and critical limits 

è

 14 Technical data.

Commissioning the vacuum generator OVEM-...-OE/-OPE

1. Apply operating pressure to supply port (1).

Ä

Negative pressure is generated at the vacuum port (2).

2. Switch on the operating voltage.

Ä

The current pressure is displayed and the vacuum generator is ready for
operation.

Commissioning the vacuum generator OVEM-...-CE/-CPE

1. Apply operating pressure to supply port (1).
2. Switch on the operating voltage.
3. Activate suction: apply input signal to pin 5.

Ä

Negative pressure is generated at the vacuum port (2). The current pres-
sure is displayed and the vacuum generator is ready for operation.

Changing the operating pressure changes the power of the negative pressure at
the vacuum port. This allows the vacuum to be adjusted. 
Functions and parameters can be specified:

manually at the device 

by teach-in 

8.3

Setting the intensity of the ejector pulse

Requirement

Vacuum generator is in operation

Procedure

1. Screw in the flow control screw 

aJ

 completely

Ä

The channel for the ejector pulse is closed. An ejector pulse is not gener-
ated.

2. Switch off vacuum generation.
3. Screw the flow control screw out or in to adjust the ejector pulse to the

required intensity.

4. Test the settings before commissioning.

8.4

Reducing the vacuum

OVEM-...-CN/-ON

Cut off the compressed air supply by switching the input voltage off (-CN) or
on (-ON).

Ä

The vacuum port 

5

 is pressurised. The workpiece is released from the

suction gripper.

OVEM-...-CE/-OE/-CPE/-OPE

Switching on the solenoid valve for ejector pulse 

1

 generates an ejector

pulse.

Ä

The vacuum port 

5

 is pressurised. The workpiece is released from the

suction gripper.

The use of large suction cups with connectors can create a device-independent
vacuum due to the interference resistance when the suction cup with connector is
detached from the workpiece.
Set up the ejector pulse accordingly.

9

Operation and use

9.1

Teach-in switching point

Change in switching pressure if the EDIT key is accidentally pressed (

£

 2 s).

Do not press the EDIT key accidentally.

The vacuum generator is preset at the factory (

è

 8.1 Quick commissioning).

These settings can be quickly adapted to the application by teach-in of a switch-
ing point.
1. Apply operating voltage.
2. Set the desired teach pressure (e.g. object gripped).
3. Press and hold the EDIT key 

aA

>

 2 s.

Ä

LED Out 

aB

 flashes.

4. Release the EDIT button 

aA

.

Ä

The current teach point (TP) minus the functional reserve is saved as the
switching point (SP) and is applied for the switching output.

9.2

Mechanical manual override

Both solenoid valves can be manually switched with the manual override.

Содержание OVEM 1P Series

Страница 1: ...arts è www festo com spareparts 4 Service Contact your regional Festo contact person if you have technical questions è www festo com 5 Product overview 5 1 Product design 1 Solenoid valve for ejector pulse eject 2 Solenoid valve for vacuum 3 Mechanical manual override 4 Supply port 1 5 Exhaust port silencer 3 6 Vacuum port 2 7 Housing with mounting hole 8 Slide for changing the filter ele ment 9 F...

Страница 2: ...ive switching pressure sensor output A Switching input negative switching without vacuum sensor Switching input positive switching Tab 6 Switching output and switching input variants Determination of switching point The switching point SP is determined from the teach point TP and the function reserve 35 SP TP 0 35 TP The hysteresis has a fixed value 5 2 2 Valve control Control of the ejector pulse...

Страница 3: ...of the screws for mounting with mounting bracket Mounting on common supply manifold OVEM B BN Mounting is possible on a common supply manifold with a max imum of 8 places OVEM C Mounting is possible on a common supply manifold with a maximum of 4 places Assembly instructions for common supply manifold OABM P è www festo com sp 7 Installation 7 1 Pneumatic installation OVEM Symbol with vacuum senso...

Страница 4: ...ed è 6 Assembly Checking operating conditions Check operating conditions and critical limits è 14 Technical data Commissioning the vacuum generator OVEM OE OPE 1 Apply operating pressure to supply port 1 Ä Negative pressure is generated at the vacuum port 2 2 Switch on the operating voltage Ä The current pressure is displayed and the vacuum generator is ready for operation Commissioning the vacuum...

Страница 5: ...tor pulse Tubing dimensioned incorrectly Replace tubing tubing dimen sions è 7 1 Pneumatic installation Workpiece is not released by the suction gripper Flow control screw closed Open flow control screw Short circuit or overload at the out put Eliminate short circuit over load Device faulty Replace device Switching output does not react in accordance with the settings Incorrect switching point tau...

Страница 6: ...h 11 ms duration half sine Vibration resistance in accordance with EN 60068 2 10 60 Hz 0 35 mm 60 150 Hz 5g Protection class III Degree of protection IP 651 Relative humidity 5 85 Interference emission as per EN 61000 6 4 Immunity to interference as per EN 61000 6 2 Maximum permissible signal line length m 20 Materials Information on materials seals NBR HNBR Information on materials housing Die ca...

Отзывы: