Festo OVEM 1P Series Скачать руководство пользователя страница 3

H-rail mounting

Type of mounting permissible only for sizes OVEM-...-05/-07/-10/-14/-20-...-B/-
BN

H-rail mounting accessories 

è

 www.festo.com/catalogue

1 H-rail mounting

2 Screw

Fig. 5 H-rail mounting

1. Attach mounting plate on H-rail mounting 

1

.

2. Attach OVEM with H-rail mounting to the H-rail and press in the direction of

the arrow.

3. Secure to the H-rail with screw 

2

.

Mounting with mounting bracket

Type of mounting permissible only for sizes
OVEM-...-05/-07/-10/-14/-20-...-B/-BN

Accessories for mounting bracket 

è

 www.festo.com/catalogue

Fig. 6 Mounting with mounting bracket

Variant

Screws

Tightening torque

OVEM-...-05/-07/-10-...-B/-BN

M5

max. 2.5 Nm

OVEM-...-14/-20-...-B/-BN

M4

max. 2.5 Nm

Tab. 9 Size and tightening torque of the screws for mounting with mounting
bracket

Mounting on common supply manifold

OVEM-...-B/-BN: Mounting is possible on a common supply manifold with a max-
imum of 8 places.
 OVEM-...-C: Mounting is possible on a common supply manifold with a maximum
of 4 places.
Assembly instructions for common supply manifold OABM-P

è

 www.festo.com/sp

7

Installation

7.1

Pneumatic installation

OVEM-...

Symbol
with vacuum sensor
(-1P/-1N)

without vacuum sensor

-QO/-GO-CN-...

-QS/-GN-CN-...

OVEM-...

Symbol
with vacuum sensor
(-1P/-1N)

without vacuum sensor

-QO/-GO-ON-...

-QS/-GN-ON-...

-QO/-GO-CE-...

-QO / -GO -...- CPE

-QS/-GN-CE-...

-QS/-GN-...-CPE

-QO/-GO-OE-…

...-QO/-GO-...-OPE

-QS/-GN-OE-...

-QS/-GN-ON-...-OPE

Tab. 10 Circuit symbols for the functions

OVEM-...

-05-...-
GN

-07-...-
GN

-10-...-
GN

-14-...-
GN

-20-...-
GN

-30-...-
GN

-05-...-
GO

-07-...-
GO

-10-...-
GO

-14-...-
GO

-20-...-
GO

-30-...-
GO

Tube length [m]

<

0.5

<

 2

<

0.5

<

 2

<

0.5

<

 2

<

0.5

<

 2

<

0.5

<

 2

<

0.5

<

 2

Min. internal diameter of tubing [mm]

- Supply port

1

2

1.5

2

2

3

3

4

4

5

6

7

- Vacuum port

2

3

3

4

4

5

5.5

6

6

7

9

11

Содержание OVEM 1P Series

Страница 1: ...arts è www festo com spareparts 4 Service Contact your regional Festo contact person if you have technical questions è www festo com 5 Product overview 5 1 Product design 1 Solenoid valve for ejector pulse eject 2 Solenoid valve for vacuum 3 Mechanical manual override 4 Supply port 1 5 Exhaust port silencer 3 6 Vacuum port 2 7 Housing with mounting hole 8 Slide for changing the filter ele ment 9 F...

Страница 2: ...ive switching pressure sensor output A Switching input negative switching without vacuum sensor Switching input positive switching Tab 6 Switching output and switching input variants Determination of switching point The switching point SP is determined from the teach point TP and the function reserve 35 SP TP 0 35 TP The hysteresis has a fixed value 5 2 2 Valve control Control of the ejector pulse...

Страница 3: ...of the screws for mounting with mounting bracket Mounting on common supply manifold OVEM B BN Mounting is possible on a common supply manifold with a max imum of 8 places OVEM C Mounting is possible on a common supply manifold with a maximum of 4 places Assembly instructions for common supply manifold OABM P è www festo com sp 7 Installation 7 1 Pneumatic installation OVEM Symbol with vacuum senso...

Страница 4: ...ed è 6 Assembly Checking operating conditions Check operating conditions and critical limits è 14 Technical data Commissioning the vacuum generator OVEM OE OPE 1 Apply operating pressure to supply port 1 Ä Negative pressure is generated at the vacuum port 2 2 Switch on the operating voltage Ä The current pressure is displayed and the vacuum generator is ready for operation Commissioning the vacuum...

Страница 5: ...tor pulse Tubing dimensioned incorrectly Replace tubing tubing dimen sions è 7 1 Pneumatic installation Workpiece is not released by the suction gripper Flow control screw closed Open flow control screw Short circuit or overload at the out put Eliminate short circuit over load Device faulty Replace device Switching output does not react in accordance with the settings Incorrect switching point tau...

Страница 6: ...h 11 ms duration half sine Vibration resistance in accordance with EN 60068 2 10 60 Hz 0 35 mm 60 150 Hz 5g Protection class III Degree of protection IP 651 Relative humidity 5 85 Interference emission as per EN 61000 6 4 Immunity to interference as per EN 61000 6 2 Maximum permissible signal line length m 20 Materials Information on materials seals NBR HNBR Information on materials housing Die ca...