DSMI-B
Festo DSMI-B 2017-12d English
14
Connect the measuring system to the connecting cable
as described in the description of the positioning controller.
The PIN assignment is shown in the table below:
Pin
Designation
Assignment
1
DC +10 V
3
1
2
4
2
Signal
1)
3
GND
4
Screen
1)
Terminating resistor: 5 kΩ
Linearity: ±0.25 %
Fig. 20
For interrogation of the end positions
with DSMI-12 ... 40-B:
Place the proximity switch (B)
SME/SMT-10
F
-...-
KL
on the groove
of the shock absorber retainer.
A sensor bracket (D
è
Accessories) is
required to fasten the proximity switch.
The proximity switch is actuated by
magnets (C) in the stop lever.
For interrogation of the end positions
with DSMI-63 ...-B:
Place the SME/SMT-8..-... proximity
sensor (B) in the sensor bracket
(E
è
Accessories).
The proximity sensor is actuated by
magnets (C) in the stop lever.
Fig. 21
(C)
(B)
(D)
Fig. 22
(C)
(B) (E)