background image

DSMI-B

Festo DSMI-B 2017-12d English

5

2

Function and application

When the compressed air ports are pressurised alternately, the inner vane in 
the housing swivels backwards and forwards. This swivel movement is transmitted
to the outer stop lever and the drive shaft as a rotary movement. The angle of 
rotation can be limited by means of adjustable stops and adjustment sleeves for
the stop lever. To use the DSMI as a measuring cylinder, the adjustment sleeve in
the shock absorber retainer can be replaced with cushioning components
(elastomer shock absorbers or shock absorbers).

The pneumatic DSMI swivel module was designed for rotating or swiveling work
loads which do not have to carry out a complete revolution. 
The integrated measuring system was designed for monitoring the swivel position
in combination with a positioning controller from Festo (e.g. CMPX, CMAX,
SPC200, SPC11 “Soft Stop”) or for use as a measuring cylinder.

If it is used as a measuring cylinder, the compressed air will need to be throttled
(e.g. using one-way flow control valves).

The device is intended for use in an industrial environment.

3

Transport and storage

Take the weight of the DSMI into account:

It weighs up to 7 kg.

Ensure the following storage conditions:

– Storage times should be kept to a minimum
– Cool, dry and shaded storage locations protected from corrosion.

Содержание DSMI-***-B Series

Страница 1: ...en Operating instructions Swivel module DSMI B 8076556 2017 12d 8076558...

Страница 2: ...ation of the original instructions Symbols Installation and commissioning may only be per formed in accordance with these instructions by technicians with appropriate qualifications Warning Caution No...

Страница 3: ...on 7 Mechanical installation 7 Adjusting the stops on the DSMI 9 Adjusting the DSMI with internal stop system 11 Installing the pneumatic system 12 Electrical installation 13 6 Commissioning 15 Commis...

Страница 4: ...ting thread for drive 2 Drive shaft 3 Compressed air ports 4 Measuring system connection 5 Adjustment sleeve with lock nut 6 Hole for earth connection 7 Stop consisting of shock absorber retainer and...

Страница 5: ...absorbers The pneumatic DSMI swivel module was designed for rotating or swiveling work loads which do not have to carry out a complete revolution The integrated measuring system was designed for monit...

Страница 6: ...d in accordance with the relevant safety guidelines if the maximum load limits are observed Take the ambient conditions at the location of use into account Corrosive environments e g ozone will reduce...

Страница 7: ...n specifications apply to the electronically controlled operation To install the mechanical system please observe the instructions in the descriptions of the positioning controller The following appli...

Страница 8: ...g specifications are fulfilled Technical data and Characteristic curves chapters It must not be tilted Permissible radial force Fz Permissible axial force Fx Permissible mass moment of inertia The mas...

Страница 9: ...e a more even movement between right hand and left hand swivel ing movements Adjusting the stops on the DSMI Note Operating the DSMI without cushioning will destroy it Make sure that the DSMI is alway...

Страница 10: ...etainers To shift the shock absorber retainers it is sufficient to slacken the locking screws until they can just barely be shifted 4 Push the shock absorber retainer towards the stop lever until the...

Страница 11: ...in the following cases For moving masses with a mass moment of inertia greater than the determined permitted mass moment of inertia When the DSMI is operated without an air cushion on the exhaust side...

Страница 12: ...on in combination with a positioning controller For electronically closed loop control of the DSMI in combination with a positioning controller Note Special installation specifications apply to the el...

Страница 13: ...essary In this way you can prevent the moving mass from moving down and hitting the bottom if there is a sudden drop in pressure Electrical installation Note Leakage currents can impair the measuring...

Страница 14: ...25 Fig 20 For interrogation of the end positions with DSMI 12 40 B Place the proximity switch B SME SMT 10F KL on the groove of the shock absorber retainer A sensor bracket D Accessories is required t...

Страница 15: ...MI is safeguarded to prevent anyone from reaching into the swivel range no objects can get there e g by means of an individual protective screen Note The mechanically set end position may change under...

Страница 16: ...ther applications e g as measuring cylinder 1 Close both upstream one way flow control valves Completely first Then open them again approximately one turn 2 Make sure that the operating conditions lie...

Страница 17: ...e test run When all necessary corrections have been made 10 End the test run Fine adjustment of the end positions Note An adjustment sleeve that is screwed out too far 5 or a shock absorber that is sc...

Страница 18: ...panner The permissible unscrewing lengths are listed in the following table DSMI B 25 40 63 Unscrewing length aD adjustment sleeve elastomer shock ab sorber mm 0 4 0 5 4 0 6 6 Unscrewing length aE sho...

Страница 19: ...e functional reliability will be impaired by excessive heating To extend the service life of the shock absorbers Apply a thin coat of grease to the stop caps of the shock absorbers To check the functi...

Страница 20: ...the mass has reached a stable position before venting e g the lowest point Recommendation Return the product to our repair service for overhaul The necessary fine adjustments and tests will then be t...

Страница 21: ...on with positioning controllers See detailed description of the relevant positioning controller Fig 30 12 Technical data DSMI B 25 40 63 Design Semi rotary vane drive with drive shaft on ball bearings...

Страница 22: ...pecifications Max swiveling frequency Hz 2 1 Protection class IP65 CE symbol see declaration of conformity www festo com4 According to EU EMC directive Materials Housing flange stop lever Anodised alu...

Страница 23: ...DSMI B Festo DSMI B 2017 12d 23...

Страница 24: ...zation is prohibited Offenders will be liable for damages All rights re served in the event that a patent utility model or design patent is registered Copyright Festo AG Co KG Ruiter Stra e 82 73734 E...

Отзывы: