DGE−...−ZR−RF
Festo DGE−...−ZR−RF 0405a English
52
F
au
lt
Reme
d
y
Po
ss
ible
caus
e
Missing or
undefined
switching functions
Proximity switch or cable defective
Fit new proximity switch or
replace cable
switching functions
Incorrect mounting of sensor
support or switching cam
Carry out settings again
Switching interval set incorrectly
Readjust
Incorrect switch or incorrect
connection
Use correct switch or
connection
Jamming
Extreme accumulation of dirt
under toothed belt
Eliminate cause and return
product to Festo
Axis badly damaged due to crash
or similar
Return product to Festo
Outside the axis (e.g. drive
package including coupling or
external attachments)
See instructions
Permitted
dynamics not
reached
Incorrect toothed belt
pre−tensioning e.g. due to belt
damage
Return product to Festo
Locking in"
atoneposition
Long standstill time at one
position
Disappears after a running
in phase
Vibration
Overloading the axis
Observe maximum loading
limits
Dynamics too high
If necessary, check
modifications to plan
Incorrect placing of centre of
gravity of work load
Shift centre of gravity
External coupling on the base
stand or in the multi−axis system
Eliminate coupling in
Motor speed
cannot be
transmitted to
Coupling loose
Tighten locking screws of
coupling
transmitted to
product
Toothed belt torn or teeth torn off
Return product to Festo
Fig.46