DGE−...−ZR−RF
Festo DGE−...−ZR−RF 0405a English
49
8
C
a
re
a
n
d
m
a
inten
a
n
c
e
S
Recommendation:
Return the product to Festo for inspection after every 10,000 kilometres run.
S
Do not adjust screws or threaded pins for which there are no direct demands
for modification in the operating instructions.
Lubricating the roller guide
S
Lubrication interval: as required, in principle at least after 10.000 km.
S
Note that lubrication must be carried out more frequently:
in dusty and dirty environments,
with very short work strokes (running−in at a position).
S
Lubricate the DGE−...−ZR−RF at the lubrica
tion nipples on both sides of the slide.
Oil: e.g. Constant OY 390 from Klüber,
München
Grease gun: see Accessories.
Fitted into restricted spaces:
S
Use blast pipe B (axial opening) or C
(radial opening) instead of the stan
dard blast pipe A.
S
Move through the rated stroke once completely in order to distribute the oil
evenly in the interior of the DGE−...−ZR−RF.
At each maintenance procedure:
S
Check that the slide is set free of play and distortion.
If you find something unusual, see the chapter Eliminating faults".
9
Rep
a
ir
s
Faults during operation
S
Make sure that the DGE−...−ZR−RF is overhauled only by our repair service (es
pecially if there is play between the slide and the guide or if the toothed belt is
loose).
In this way you can prevent damage to your axis at a later stage. The repair
procedure requires settings with very fine adjustments.