DGE−...−ZR−RF
Festo DGE−...−ZR−RF 0405a English
34
In order to connect the motor block and the DGE−...−ZR−RF:
S
Use a coupling housing (C) which is suited to your coupling
(if necessary, order separately).
S
Use a connecting flange (L) with suitable hole pattern.
The connecting flange adapts the hole pattern to that of the motor block and
coupling housing.
1. Push the slide into the centre of the stroke.
2. Place the centering disc (B) into the centering recess (A)
(only with sizes 40 and 63, see Fig. 12).
A
B
C
D
E
F
K
G
H
I
L
M
Fig.12
3. Mount the connecting elements coupling hub (D), gear ring (E) and coupling
hub (F), at the same time observing dimension s (see Fig. 13).
Clean the drive shaft and the connecting elements. The coupling will only grip
without slipping on a drive shaft which is dry and free of grease.