13
Technical data
General technical data
Ambient temperature
[°C]
–
20
…
+50
Storage temperature
[°C]
–
40
…
+70
Humidity
(non-condensing)
[%]
5
…
95
Permissible setup alti-
tude above sea level
[m]
2000 (max.)
Number of modules per
interface
Depending on the interface
è
Instructions for the respective interface
Max. cable length for
system communication
between 2 modules
[m]
50 (available cable
è
www.festo.com/cataloguelengths)
Address volume of the
inputs/outputs
[Bytes]
2048/2048 (depending on interface)
Degree of protection in
accordance with
EN 60529
IP65/IP67
1)
(if lines are connected and connections that are not required are
closed with a cover cap)
Protection against elec-
tric shock (protection
against direct and
indirect contact in
accordance with
IEC 61010-1)
through the use of SELV/PELV circuits
(safe extra-low voltage/protected extra-low voltage)
CE marking
In accordance with EU EMC Directive
See declaration of conformity
è
Electromagnetic com-
patibility
See declaration of conformity
è
Mounting position
Any
1) May differ for some valve terminals
Tab. 17 General technical data