11.5
Diagnostic messages
ID hex (dec)
Message
Description
A short-circuit/overload of the sensor supply was detec-
ted.
Remedy
–
Check connected load for correct function,
in particular for power consumption.
–
Check sensor and wiring.
01
|
01
|
010B
(16843019)
Short circuit/overload
in sensor supply
Diagnost-
ic status
Error
Short circuit/overload in output signal.
Remedy
–
Check connected load for correct function,
in particular for power consumption.
–
Check wiring.
01
|
01
|
010C
(16843020)
Output signal short-
circuit/overload
Diagnost-
ic status
Error
Undervoltage of the logic supply PS 24 V DC was detec-
ted.
Remedy
–
Check logic supply PS.
02
|
01
|
0016
(33619990)
Undervoltage in logic
supply PS 24 V DC
Diagnost-
ic status
Warning
Error
Overvoltage in the logic supply PS 24 V DC detected.
Remedy
–
Check logic supply PS.
02
|
01
|
0017
(33619991)
Overvoltage in logic
supply PS 24 V DC
Diagnost-
ic status
Error
Undervoltage in the load supply PL 24 V DC detected.
Remedy
–
Check load supply PL.
02
|
01
|
0105
(33620229)
Undervoltage in load
supply PL 24 V DC
Diagnost-
ic status
Error
A switch-off of the load supply PL was detected. The cause
can be a deliberate shutdown by the emergency stop.
Remedy
–
Check if the emergency stop was activ-
ated.
–
Check load supply PL.
02
|
01
|
0106
(33620230)
Switch-off load supply
PL 24 V DC
Diagnost-
ic status
Information
Diagnostics
27
Festo — CPX-AP — 2019-06