8
Commissioning
NOTICE!
Malfunction due to switching on the higher-order controller and automation system CPX-AP in the
incorrect order.
•
Switch on the higher-order controller and automation system CPX-AP according to the preset
order of the network used.
1. Using the appropriate software, set up an automation project for the higher-order controller.
2. Import the device description file into the software
è
3. Configure the automation system CPX-AP in the software:
–
System structure
–
Network addressing
–
Address assignment of modules
è
Instruction manual for automation system CPX-AP
4. Transfer the automation project to the higher-order controller.
Behaviour of the display components of the module after error-free commissioning
[MD]
[SD]
[PL]
[MT]
Illuminated green
Illuminated green
Illuminated green
Off
Tab. 8 Behaviour of the display components after error-free commissioning
[XF1], [XF2]
[NF]
[PE]
Illuminated green
1)
Off
Off
1) only when cable is connected to [XF1] or [XF2]
Tab. 9 Behaviour of the display components after error-free commissioning
Information on troubleshooting in the event of incorrect behaviour:
è
Instruction manual for automation system CPX-AP
è
10 Diagnostics and fault clearance
9
Parameterisation
Various parameters are available for reading out information about the modules in an automation sys-
tem CPX-AP and adapting the modules to the application situation.
Write access to the parameters is typically performed by the higher-level controller using the device
descriptions specific to the host system.
Commissioning
10
Festo — CPX-AP-I-PN-M12 — 2019-06