ID hex (dec)
Message
Description
A switch-off of the load supply PL was detected. The cause
can be a deliberate shutdown by the emergency stop.
Remedy
–
Check if the emergency stop was activ-
ated.
–
Check load supply PL.
02
|
01
|
0106
(33620230)
Switch-off load supply
PL 24 V DC
Diagnost-
ic status
Information
Overvoltage in the load supply PL 24 V DC
Remedy
–
Check load supply PL.
02
|
01
|
013F
(33620287)
Overvoltage in the
load supply PL
24 V DC
Diagnost-
ic status
Error
The AP system communication to a module is aborted.
Remedy
–
Restart AP system.
–
Check the cable.
08
|
01
|
0127
(134283559)
Communication to AP
module interrupted
Diagnost-
ic status
Error
The device description file stored in the device at the fact-
ory is invalid or missing.
Remedy
–
Restart device.
–
Check AP system communication.
–
Check firmware version.
–
In the event of repeated errors, contact
Festo Service.
0B
|
09
|
0128
(185139496)
APDD invalid
Diagnost-
ic status
Error
The start-up device description file stored in the device at
the factory is invalid or missing.
Remedy
–
Restart device.
–
Check AP system communication.
–
Check firmware version.
–
In the event of repeated errors, contact
Festo Service.
0B
|
09
|
0129
(185139497)
Start-up APDD invalid
Diagnost-
ic status
Error
Tab. 11 Diagnostic messages
Diagnostics and fault clearance
13
Festo — CPX-AP-I-PN-M12 — 2019-06