Adjusting the CP application module and fixing it on the CP Factor basic module
•
Use raised head screws M5x8, in order to connect the mounting brackets (1) of the CP application
module Measuring, at first loosely, with the cross profiles (2) of the CP Factory basic module.
•
After setting all raised head screws, you can still move the CP application module to the position
required.
•
Push a carrier with pallet and front cover to the stopper position. The front cover points with its inside
upwards. The drilled hole of the front cover is on the left side.
•
Have a visual inspection to make sure that the two distance sensors are capable of registering the front
cover more or less in medium range.
•
Now tighten the raised head screws.
•
Then put the black covers onto the mounting brackets.
Tightening the CP application module / illustration similar
Position
Description
1
CP application module: mounting bracket with cover
2
CP Factory basic module: cross profile
Содержание CP-AM-MEAS
Страница 1: ...Festo Didactic 8154245 en 03 2022 8154245 Measuring CP Factory CP Lab Original operating instructions ...
Страница 20: ...Basic safety instructions 20 Festo Didactic 8154245 en 4 11 CE Declaration of Conformity ...
Страница 21: ...Basic safety instructions Festo Didactic 8154245 en 21 ...
Страница 22: ...Basic safety instructions 22 Festo Didactic 8154245 en ...
Страница 26: ...Technical data 26 Festo Didactic 8154245 en Illustration similar ...
Страница 37: ...Design and function Festo Didactic 8154245 en 37 6 6 1 Measuring chain CP Lab ...
Страница 39: ...Design and function Festo Didactic 8154245 en 39 6 6 2 Measuring chain CP Factory ...
Страница 69: ...Operation Festo Didactic 8154245 en 69 3 Change to Setup mode page 4 Choose application ...