– A CP valve terminal with CP connection always oc-
cupies 16 output addresses, irrespective of how
many valve solenoid coils are fitted on it. Therefore
only one valve terminal can be connected to each
string. This enables the valve terminal to be ex-
tended at a later stage without the need for the ad-
dress range to be shifted.
CP valve
terminal
1
In the case of CPV valve terminals with 4, 6 or 8 valve
locations 16 output addresses are allways assigned.
With CPA valve terminals 16 output addresses are also
assigned (2...16 valve locations).
Fig. 1/6: Address assignment on a CP valve terminal
as an example
– Altogether, a maximum of 64 valve solenoid coils can
be addressed per node.
2-3
4-5
6-7
8-9
10-11
12-13
14-15
0-1
1
1. System overview
1-14