A valve location occupies 1 or 2 addresses on the CPA
valve terminal, depending on the manifold block.
CPA valve
terminal
1
2
1
2
Electrical bridge for single soelnoid or double solenoid
valves with manual override and LEDs
Electrical manifold block (EV1 or EV2)
Fig. 1/8: Manifold blocks of the CPA valve terminal
Manifold block
Number of occupied outputs
Type ..-EV1
1 output
Type ..-EV2
2 outputs
– If a manifold block is not used (reserve plate location,
pressure supply), the relevant addresses will still be
assigned.
1. System overview
1-16
CP... 9806A