1.3 Fieldbus baud rate and fieldbus length
PLEASE NOTE
The CP system sets itself automatically to one of the
baud rates below.
The maximum permitted fieldbus length depends on the
baud rate used. The baud rates which can be used are
shown in the table below.
Baud rate (in kBaud)
Fieldbus length (max.)
9.6
1200 m
19.2
1200 m
93.75
1200 m
187.5
1000 m
500
400 m
1500
200
m
3000 - 12000
100 m
1. Installation
1-10
CP FB13-E 9904b