6. Technical specificationsElectrical installation
Festo.P.BE-CMMS-ST-HW-EN 0903b
101
DIP switches
ON/OFF
Meaning
9
ON
DIP switch 9 is the low-value bit.
00 = 125 kBaud
01 = 250 kBaud (example)
10 = 500 kBaud
11 = 1000 kBaud
10
OFF
Tab. 6.16: Sample baud rate
6.5
Instructions on safe and EMC-compliant
installation
6.5.1
Explanations and terms
Electromagnetic compatibility (often abbreviated to EMC) or electromagnetic interference
(EMI) involves the following requirements:
Interference
immunity
Sufficient interference immunity of an electrical system or electrical
device against external electrical, magnetic or electromagnetic
noise via lines or space.
Interference
emission
Sufficiently low interference emission of electrical, magnetic or
electromagnetic interference of an electrical system or an electrical
device on other devices in the environment via lines and space.
6.5.2
General information on EMC
Interference emission and resistance to interference of a stepping motor controller always
depend on the complete design of the drive, which consists of the following components:
Components
-
Voltage supply
-
Stepper motor controller
-
Motor
-
Electromechanics
-
Design and type of wiring
-
Higher-order control system
In order to increase the interference immunity and decrease the interference emission, the
CMMS-ST already has integrated motor throttles and mains filters, which means that the
CMMS-ST stepping motor controller can be operated without additional screens and filters
in most applications.
Содержание CMMS-ST-C8-7
Страница 2: ......
Страница 78: ...4 Functional safety engineering 78 Festo P BE CMMS ST HW EN 0903b Circuitry example ...