8. Technical specificationsService functions and error messages
Festo.P.BE-CMMS-ST-HW-EN 0903b
111
Error message
Meaning of error
message
Measures
Error
reaction
Main
index
Sub-
index
29
0
No SD present
Tried to access missing SD card.
Warn
1)
1
SD initialisation error
Error on initialisation / Communication not
possible
PS off
1)
2
SD parameter record error Checksum incorrect / File missing /
Incorrect file format
PS off
1)
3
SD full error
Parameter cannot be saved to CD as the
memory capacity is not sufficient.
PS off
1)
31
0
I²t motor
Motor blocked?
Warn
1)
1
I²t servo controller
Check power dimensioning
of drive package.
PS off
1)
35
1
Time out with fast stop.
Increase Quick Stop ramp
PS off
40
0
Software limit stop
positive
Warn
1)
1
Software limit stop
negative
2
Target position behind
negative software end
switch
3
Target position behind
positive software end
switch
41
8
Record linking:
Unknown command
Unknown record linking extension found
PS off
1)
9
Record linking:
Jump target error
Jump to a line outside permitted range
42
1
Positioning:
Error in pre-calculation
The positioning target cannot be reached due to
the positioning options or the parameters.
Check the parameterization of the affected
positioning records.
PS off
1)
9
Positioning:
Position data record error
Acceleration too low for v_max.
PS off
43
0
Limit switch negative
Warn
1)
1
Limit switch positive
9
Limit switches:
Both active
Check parameters, wiring and limit switches.
Содержание CMMS-ST-C8-7
Страница 2: ......
Страница 78: ...4 Functional safety engineering 78 Festo P BE CMMS ST HW EN 0903b Circuitry example ...