7. Parameters
22
Festo
P.BE-CMMS-FHPP-DN-SW-EN
en
1103a
Allocation Name
Attribute
FHPP-PNU
Type
Torque: Actual value
4
301,1
DINT
Torque: Setpoint 5
301,2
DINT
Torque
Torque: Actual deviation
6
301,3
DINT
Digital Inputs: DIN0 … 7
10
303,1
USINT
Digital Inputs: DIN 8 … 11
11
303,2
USINT
Digital
inputs/outputs
Digital Outputs: DOUT 0 … 3
20
304,1
USINT
Demand record number
32
400,1
USINT
Actual record number
33
400,2
USINT
Date record control
Record status byte
34
400,3
USINT
(maintenance
parameter)
Operating hour meter
35
305,3
UDINT
Velocity: Actual value
36
310,1
DINT
Velocity: Demand value
37
310,2
DINT
Speed
Velocity: Actual deviation 38
310,3
DINT
Notification of
remaining distance
Remaining distance for message
56
1230,1
UDINT
Table 7.3 Process Data
7.3
Project Data
This object supplies project information, i.e.common parameters for all devices of a
machine.
Object Class ID:
105
Number of Instances:
1
Assignment Name
Attribute
FHPP-PNU
Type
Project zero point
1
500,1
DINT
Negative position limit
2
501,1
DINT
Positive position limit
3
501,2
DINT
Max. speed
4
502,1
UDINT
Max. acceleration 5
503,1
UDINT
General project data
Max. jerkfree filter time
7
505,1
UDINT
Teach Teach
target
20
520,1
USINT
Table 7.4 Project Data