4. Activating and configuring DeviceNet
Festo
P.BE-CMMS-FHPP-DN-SW-EN
en
1103a
15
4.
Activating and configuring DeviceNet
4.1
Activation of DeviceNet
The inserted DeviceNet module will be recognized automatically when the motor controller
is switched on. n order to activate, you must deactivate the CAN interface with DIP switch
11 at the CMMS/CMMD motor controller.
A unique MAC ID must be assigned to each device in the network. The MAC ID must be set
with DIP switches 1 … 6 on the motor controller.
The baud rate must be set with DIP switches 9 and 10.
1
DIP switch 1 ... 6 (MAC-ID)
2
DIP switch 11
3
CAMC-DN slot
Fig. 4.1 DIP switch
DIP switch
Meaning
1
2
3
4
5
6
MAC ID.
See example
7 Reserved
8
Bootloader (If the switch is set to ON, the system searches for new firmware on the SD
card)
9 Transmission
rate
1
2
3